The 

Log a Single Entry

 command causes logging to start, collect one single entry, and 

immediately stop again.  This function is not available when logging is already running. 

Click 

Clear Log

 to discard any data that has already been collected.  If there is data in memory, 

which has not been saved to disk, this function displays a prompt asking to verify it is OK to discard 
the data. If the log is running when this function is clicked, the log continues running after the 
existing data is discarded. 

Click 

Save Log

 to save the collected log data to a csv file.  This stops the logging function, if it is 

active, and displays a file dialog box to specify where to store the logged data.  The default file 
name is described in the 

Log Status and Control Information

 section, but the file name may be 

changed if desired. 

4.2.3  Help Menu 

The Help menu contains a single function: About. 

Figure 6. Help Menu 

 

The 

About

 function displays a dialog box (Figure 7) showing the version and copyright information 

for the application and library. Click the 

OK

 button to close this window and continue. 

Figure 7. About Widow 

 

4.3 

System Level Controls 

Immediately below the top menu bar there are checkboxes used to control the system level 
functions of the TSL2540 device.  

The 

Power-On

 checkbox controls the PON function of the TSL2540. When this box is checked, the 

power is on and the device can operate. When this box is unchecked, the power is off and the 
device does not operate (The control registers can still be written, but the device does not function). 

The 

ALS Enable

 checkbox controls the AEN function of the TSL2540. When this box is checked, 

the device collects and report ALS data as programmed. When this box is unchecked, the ALS 
functions do not operate. 

Summary of Contents for TSL2540 EVM

Page 1: ...User guide TSL2540 EVM TSL2540 ALS Light to Digital Sensor Evaluation Kit Version 1 0 ...

Page 2: ...s 3 2 Getting Started 3 3 Hardware Description 3 4 Software Description 4 4 1 Connect Software to Hardware 4 4 2 System Menus 5 4 3 System Level Controls 6 4 4 Auto Polling 7 4 5 Device ID Information 7 4 6 Log Status and Control Information 7 4 7 ALS Tab 8 5 Resources 10 ...

Page 3: ...s loads the required driver for the USB interface and also the device s graphical user interface GUI The balance of this document identifies and describes the controls available on the GUI In combination with the TSL2540 datasheet the QSG and application notes available on the ams website www ams com there should be enough information to allow evaluation of the TSL2540 device 3 Hardware Descriptio...

Page 4: ...he lux Figure 3 Software Main Window 4 1 Connect Software to Hardware On startup the software automatically connects to the hardware On successful initialization the software displays a main window containing controls pertinent to the connected device If the software detects an error an error window appears If Device not found or is unsupported appears verify the correct daughterboard is properly ...

Page 5: ...ers are continually read while the program is running The Lux Coefficients menu allows the user to Display Load or Save the lux coefficients used to calculate lux See ALS Lux Coefficients section for more details Click on the Exit command to close the main window and terminate the application Any unsaved log data is cleared from memory The application can also be close by clicking the red X in the...

Page 6: ...tion section but the file name may be changed if desired 4 2 3 Help Menu The Help menu contains a single function About Figure 6 Help Menu The About function displays a dialog box Figure 7 showing the version and copyright information for the application and library Click the OK button to close this window and continue Figure 7 About Widow 4 3 System Level Controls Immediately below the top menu b...

Page 7: ...hese fields are changed the new values are stored with any new data logged The default log file name is based on these values at the time the log file is written If nothing is entered in these boxes they default to a period Sample default file name TSL2540_1 2 3_Log_HH_MM_SS csv From Application From User Input The Count value displayed is a count of the number of samples currently in the log buff...

Page 8: ...es of WTIME and WLONG are ignored The WTIME control sets the time to wait between ALS cycles WTIME can be adjusted in 2 778ms steps The WLONG checkbox controls sets the WTIME factor When this box is checked the wait time between ALS cycles is extended by a factor of 12x 4 7 2 ALS Lux Coefficients The TSL2540 ALS supplies information that is used to calculate Lux unit of illumination The Lux equati...

Page 9: ...ng utf 8 Device TSL2540 Saved 9 22 2017 4 22 11 PM luxeq eq_values coef name DGF value 58 514 coef name CoefB value 0 202 coef name CoefC value 0 893 coef name CoefD value 0 147 eq_values luxeq 4 7 3 ALS Output Data The top right corner of the ALS tab displays the output data This data is continuously read The polling interval is shown above the tab Visible displays the data counts for the Visible...

Page 10: ...d but the actual plot will not be updated until the plot function is re enabled 5 Resources For additional information regarding the TSL2540 please refer to the datasheet For information regarding the installation of the TSL2540 EVM host application software please refer to the TSL2540 EVM Quick Start Guide Designer s Notebooks dealing with various aspects of optical measurement and optical measur...

Page 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information ams TSL2540 EVM ...

Reviews: