│ 33
Figure 44:
NanEyeXS Manual Register Control
Figure 45:
NanEyeM Manual Register Control
The NanEyeM/XS Expert Registers tab (Figure 46) shows the different registers. To configure the
sensor to idle mode, the user needs to first deactivate the “Automatic sensor power cycling” and then
insert the value 1 into IdleMode register. The inverse procedure will remove the sensor of the idle
mode. Please note that this feature is not available in the NanEye2D sensor.
Information
The “Automatic sensor power cycling” option is a unique feature of the Fiber Optic Box evaluation
kit and specifically developed to NanEyeM/NanEyeXS, once these sensors have the Idle Mode
feature. It is not available for the NanEye2D sensor and NanoUSB2.2 evaluation kit.