Pos side of selected channel 

 

Little Speedy 

LS - 3030 

 

target distance should be 
between 1 / 8 to 3 / 8. 

Target 

+ 20 to 28 VDC 

Step 4 

 

Make electrical connections as follows: 

 

*

 Input Power ( 28 VDC ):  

 The LS-3030 is an ANALOG  OUTPUT device with a 28  

 

VDC power input on the BLACK wire and producing a 4-20 mA current on the white wire.   

 

This output can be used in conjunction with a computer monitoring system to indicate belt  

 

speed in FPM.  The output is a  standard 0-3 VDC analog output:  OFFSET = 0, GAIN is  

 

dependent on roller size and the number of targets.  Contact factory for further assistance in  

 

using this feature.    

SPAN 
 
LED 
 
ZERO 

Step 5

   

 

Now that the LS -3030 has been mounted,  it can be calibrated.  Connect the Multimeter in  

 

line with the neutral and set the meter to read mA.   

 
 

With the belt off the multimeter should read  4 mA on the output.  If not, locate the zero  

 

potentiometer.  Using screwdriver, rotate the pot. counterclockwise till the multimeter reads 4 mA.   

 
 

Now that the Zero Calibration has been set it is time to turn the belt on and adjust the span. With the 

 

belt operating under normal conditions, the multimeter should read 12 mA.  If not, locate the span 

 

pot, and rotate the adjustment until the multimeter read 12 mA.  

 

 

 

   

 

The LED, located between the two pots. will illuminate only when the target moves across the sensor 

 

head of the Little Speedy. 