Copyright 2021 Ampt LLC.
All rights reserved.
34
V600-13.5 String Optimizer Platform
Installation Manual: 57070020-1 A
12.8 A models (V550 - V600)
Vxxx-13.5-12.8 Models
V550
V575
V600
Model Number
31570015-0550
31570015-0575
31570015-0600
Electrical
Input
Maximum voltage per input¹
V
600
600
600
Maximum current (Imp) per input²
A
12.8
12.8
12.8
Maximum short-circuit
current (Isc) per input
A
13.5
13.5
13.5
MPP tracking voltage range
V
190 - 585
190 - 585
190 - 585
Startup voltage per input
V
400
400
400
Number of inputs
2
2
2
Output
Output voltage range
V
0 - 550
0 - 575
0 - 600
Output voltage at full power
V
465
490
515
Output voltage at zero power
V
550
575
600
Maximum output current
A
12.8
12.8
12.8
Maximum continuous output power
kWdc
5.8
6.1
6.4
Efficiency (max / CEC / Euro)
%
99.5 / 99.3 / 99.2
Mechanical
Input & output connector
Amphenol H4
Dimensions
10.71” x 8.66” x 3.94”
(272 mm x 220 mm x 100 mm)
Weight
9.0 lbs. (4.1 kg)
Ambient temperature
operating range
-40 °F to +122 °F
(-40 °C to +50 °C)
Cooling
Convection
Environmental
Environmental category
Outdoor
Pollution degree
2
Maximum operating altitude³
9843 ft (3000 m)
Overvoltage category
OVII
Ingress protection
IP66 / 4X
General
Compliance
ETL to UL 1741;
IEC 61000-6-1, 61000-6-3, 62109; CE;
Giteki 2-1-19; FCC Part 15, class A
1. Voc at coldest design temp. Follow Ampt’s design guidelines to determine the number of modules per input and max. system v
oltage.
2. Maximum Imp of modules on the input at standard test condition (STC) - irradiation level of 1000 W/m² at 25°C.
3. Optimizer derates above this altitude.