Copyright 2018-2020 Ampt, LLC.
All rights reserved.
30
Ampt String Optimizer V1500 Series
Installation Manual: 57070012-1H
Markings
20A Models
V1250-20
V1275-20
V1300-20
V1325-20
V1350-20
V1400-20
V1450-20
V1475-20
Ampt model number
31570020-
1250
31570020-
1275
31570020-
1300
31570020-
1325
31570020-
1350
31570020-
1400
31570020-
1450
31570020-
1475
Maximum voltage per input (Vdc)
1500
1500
1500
1500
1500
1500
1500
1500
Operating voltage range per input
(Vdc)
400
–
1300
400
–
1300
400
–
1300
400
–
1300
400
–
1300
400
–
1300
400
–
1300
400
–
1300
Maximum current per input
(Imp@STC) (Adc)
12.8
12.8
12.8
12.8
12.8
12.8
12.8
12.8
Max PV short-circuit current per input
(Adc)
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
Output voltage range (Vdc)
0-1250
0-1275
0-1300
0-1325
0-1350
0-1400
0-1450
0-1475
Maximum output current (Adc)
20
20
20
20
20
20
20
20
Maximum continuous output power
(kWdc)
22.8
23.3
23.8
24.3
24.8
25.8
26.7
27.2
Ambient temperature operating range -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C
Enclosure type
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X
16A Models
V1250-16
V1275-16
V1300-16
V1325-16
V1350-16
V1400-16
V1450-16
V1475-16
Ampt model number
31570021-
1250
31570021-
1275
31570021-
1300
31570021-
1325
31570021-
1350
31570021-
1400
31570021-
1450
31570021-
1475
Maximum voltage per input (Vdc)
1500
1500
1500
1500
1500
1500
1500
1500
Operating voltage range per input
(Vdc)
400
–
1300
400
–
1300
400
–
1300
400
–
1300
400
–
1300
400
–
1300
400
–
1300
400
–
1300
Maximum current per input
(Imp@STC) (Adc)
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
Max PV short-circuit current per input
(Adc)
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
Output voltage range (Vdc)
0-1250
0-1275
0-1300
0-1325
0-1350
0-1400
0-1450
0-1475
Maximum output current (Adc)
16
16
16
16
16
16
16
16
Maximum continuous output power
(kWdc)
18.5
18.9
19.3
19.7
20.1
20.9
21.6
22.0
Ambient temperature operating range -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C -40°C - 50°C
Enclosure type
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X
IP 66/4X