6
the current readings:
MAX:
The highest measurement recorded.
MIN:
The lowest measurement recorded.
MAX-MIN:
The difference of the highest and the
lowest measurement.
AVG:
The average values of the measurements.
Press “
MIN/MAX
” key over two seconds to exit the
function. In this mode, press “
HOLD
” key to stop
recording, all values are frozen, press “
HOLD
” key again
to restart recording. In this mode, the APO function and
other keys are disabled, excluding “
HOLD
” and Back-
light keys. Press and hold down the “
MAX/MIN
” key for
more than 2 seconds to exit the MAX/MIN function.
“HOLD” Button
Press the “
HOLD
” key to enter the data hold mode, the
“
HOLD
” annunciator is displayed at the center-left of
display. When data hold mode is selected, the meter held
the present readings and stops all further measurements.
Press the “
HOLD
” key again to cancel data hold mode,
causing meter to resume taking measurements.
“WB/DP” Button
In the NTC data Mode, the Meter displays ambient
temperature when first turned on. To display wet
bulb(WB) temperature, press “
WB/DP
” key once.
Press the “
WB/DP
” again to switch to dew point(DP)
temperature. Press “
WB/DP
” a third time returns the
Meter to ambient temperature.
“K/NTC/K-DP” Button
Press the “
K/NTC/K-DP
” key, the meter can cycle through
“
K-TYPE
”, “
NTC
”, “
KDP
”.
*K-DP = K-TYPE temperature minutes Dew point
temperature.