Limited Warranty and Limitation of  Liability

Your Amprobe product will be free from defects in material 
and workmanship for 1 year from the date of purchase. This 
warranty does not cover fuses, disposable batteries or damage 
from accident, neglect, misuse, alteration, contamination, or 
abnormal conditions of operation or handling. Resellers are not 
authorized to extend any other warranty on Amprobe’s behalf. 
To obtain service during the warranty period, return the product 
with proof of purchase to an authorized Amprobe Test Tools 
Service Center or to an Amprobe dealer or distributor. See Repair 
Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. 
ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR 
STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR 
A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY 
DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY 
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES 
OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some 
states or countries do not allow the exclusion or limitation of an 
implied warranty or of incidental or consequential damages, this 
limitation of liability may not apply to you.

Repair

All test tools returned for warranty or non-warranty repair or 
for calibration should be accompanied by the following: your 
name, company’s name, address, telephone number, and proof of 
purchase. Additionally, please include a brief description of the 
problem or the service requested and include the test leads with 
the meter. Non-warranty repair or replacement charges should be 
remitted in the form of a check, a money order, credit card with 
expiration date, or a purchase order made payable to Amprobe® 
Test Tools.

In-Warranty Repairs and Replacement – All Countries

Please read the warranty statement and check your battery before 
requesting repair. During the warranty period any defective test 
tool can be returned to your Amprobe® Test Tools distributor 
for an exchange for the same or like product. Please check the 
“Where to Buy” section on www.amprobe.com for a list of 
distributors near you. Additionally, in the United States and 
Canada In-Warranty repair and replacement units can also be 
sent to a Amprobe® Test Tools Service Center (see next page for 
address).

Summary of Contents for PM-60

Page 1: ...Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso PM 60 Pocket Meter ...

Page 2: ......

Page 3: ...PM 60 Pocket Meter Users Manual 2009 Amprobe Test Tools All rights reserved Printed in China English ...

Page 4: ...xclusion or limitation of an implied warranty or of incidental or consequential damages this limitation of liability may not apply to you Repair All test tools returned for warranty or non warranty repair or for calibration should be accompanied by the following your name company s name address telephone number and proof of purchase Additionally please include a brief description of the problem or...

Page 5: ...auga ON L4Z 1X9 Tel 888 993 5853 Tel 905 890 7600 Fax 425 446 6390 Fax 905 890 6866 Non Warranty Repairs and Replacement Europe European non warranty units can be replaced by your Amprobe Test Tools distributor for a nominal charge Please check the Where to Buy section on www amprobe com for a list of distributors near you Amprobe Test Tools Europe In den Engematten 14 79286 Glottertal Germany tel...

Page 6: ...1 LCD Display 2 Hold function key 3 Function selection key 4 Range key 5 Function Selector 6 Test Leads 6 1 2 3 4 5 PM 60 Pocket Meter ...

Page 7: ...1 CONTENTS SYMBOLS 2 UNPACKING AND INSPECTION 3 INTRODUCTION 3 OPERATION 4 SPECIFICATION 8 MAINTENACE 13 TROUBLE SHOOTING 13 Battery Replacement 14 ...

Page 8: ...ce cleaning battery replacement fuse replacement etc Complies with European Directives Conforms to relevant Australian standards Do not dispose of this pruduct as unsorted municipal waste Contact a qualified recycler for disposal W Warning To ensure safe operation and service of the Meter follow these instructions Failure to observe warnings can result in severe injury or death Do not operate this...

Page 9: ...nuity diodes or capacitance To reduce the risk of fire or electric shock do not expose this product to rain or moisture UNPACKING AND INSPECTION Your shipping carton should include 1 PM 60 Meter 2 Battery GPA76P 1 5V 1 User s Manual If any of the items are damaged or missing return the complete package to the place of purchase for an exchange Introduction This meter PM 60 can be measured voltage r...

Page 10: ...der will operate continuously with LCD display flashing in two situations in the Data Hold mode 1 The Meter measure a signal different from the LCD reading 2 The measured signal is the same unit as the LCD reading and is larger 50 counts than the LCD reading ...

Page 11: ...5 Auto Range Manual Range Selecting Function ...

Page 12: ... diode mode LCD displays bad when measuring a diode conducted at forward and reverse bias LCD displays capacitance mode when no measurement at Auto sense mode Under Auto sense mode do not measure a broken component a unknown component or a component with mixed electrical characteristic such as measuring a resistor and a capacitor in parallel The meter may display incorrectly ...

Page 13: ...ds to the circuit or device connect the black lead first then connect the red lead when removing the test leads remove the red lead first then remove the black lead Volt Sense The number of dashes displaying on the LCD indicates the electric field intensity ...

Page 14: ...ec Polarity Indication Automatic positive implied Overrange display OL or OL Unit symbol indication Automatic power off time Approximately 20 minutes after power on Low battery indicator Display on LCD Power requirement 1 5V x 2 batteries Battery life 50 hours GPA76P Environmental Conditions Indoor Use Calibration One year calibration cycle Operating temperature 0 C 32 F 30 C 86 F 80 RH 30 C 86 F ...

Page 15: ...10 1 300V CAT Ⅲ 600V CAT II CAT Application field Ⅰ The circuits are not connected to mains Ⅱ The circuits are directly connected to Low voltage installation Ⅲ The building installation Ⅳ The source of the Low voltage installation Operating altitude 2000m 6562 ft Pollution degree 2 EMC EN 61326 1 Dimensions WxHxD 56 x 12 x 112 mm 2 2 x 0 5 x 4 4 in Weight 115g 0 25 lb Accessories Battery installed...

Page 16: ...erload protection 600V rms Function Ranges Resolution Accuracy DCV 400 0mV 0 1mV 0 7 5 D 4 000V 0 001V 0 6 2 D 40 00V 0 01V 400 0V 0 1V 600V 1V 0 7 5 D Input Impedance 10Me 100pF Overload protection 600V rms Function Ranges Resolution Accuracy ohm 400 0 0 1 0 9 5 D 4 000K 0 001K 0 9 2 D 40 00K 0 01K 400 0K 0 1K 4 000M 0 001M 1 5 5 D 40 00M 0 01M Open Circuit Voltage 0 4V There is a little rolling ...

Page 17: ... Measuring Time 30sec 400 0µF range 10sec 40 0µF range 3sec other range Overload protection 600V rms Function Ranges Resolution Accuracy Hz 40 00Hz 0 01Hz 0 3 5 D 400 0Hz 0 1Hz 4 000KHz 0 001KHz 40 00KHz 0 01kHz Sensitivity 10Vp p 40KHz range 1 5Vp p other range The signal must have positive and negative waveform of a cycle Max Sensitivity 600V rms Overload protection 600V rms Function Ranges Reso...

Page 18: ...l 350µA Open Circuit Voltage Max 1 8V DC Input Protection 600V rm EMC EN61326 1 This product complies with requirements of the following European Community Directives 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage as amended by 93 68 EEC CE Marking However electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit Mea...

Page 19: ...rbons or chlorinated solvents for cleaning If the meter is not to be used for periods of longer than 60 days remove the batteries and store them separately Do not attempt to repair this Meter It contains no user serviceable parts Repair or servicing should only be performed by qualified personnel TROUBLE SHOOTING If the instrument fails to operate check batteries and test leads etc and replace as ...

Page 20: ...ps should then be replaced by qualified technician Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service Battery Replacement Refer to the following figure to replace the batteries ...

Page 21: ...15 ...

Page 22: ......

Reviews: