9
Measuring AC or AC+DC Current (True rms)
See Additional Features to find out the advantages of true rms.
1. Set the Function Switch to a current function and
range,
μA
,
mA
, or
10A
.
2. If
DC
is displayed, press the yellow button to turn on
AC
or
AC+DC
.
3. If the
μA
or
mA
function is selected and
RANGE
is
displayed, press the
RANGE
button to enable autoranging.
4. Connect the Test Leads: Red to
mA
or
10A
, Black to
COM
5. Turn off power to the circuit being measured.
6. Open the test circuit (
X
) to establish measurement
points.
7. Connect the Test Probes in series with the load (to the
measurement points).
8. Turn on power to the circuit being measured.
9. Read the display, and, if necessary, correct any
overload (
0o
) conditions.
5
8
6
7
1
4
2
3
9
38XR-A