![Ampro COM 830 Reference Manual Download Page 80](http://html1.mh-extra.com/html/ampro/com-830/com-830_reference-manual_2935339080.webp)
Chapter 4
BIOS Setup Description
74
Reference Manual
COM 830
Watchdog Configuration Submenu
Feature
Options
Description
POST Watchdog
Disabled
30sec
1min
2min
5min
10min
30min
Select the timeout value for the POST watchdog.
The watchdog is only active during the power-on-
self-test of the system and provides a facility to
prevent errors during boot up by performing a reset.
Runtime Watchdog
Disabled
One time trigger
Single Event
Repeated Event
Selects the operating mode of the runtime watchdog.
This watchdog will be initialized just before the
operating system starts booting.
If set to '
One time trigger'
the watchdog will be
disabled after the first trigger.
If set to
'Single event'
, every stage will be executed
only once, then the watchdog will be disabled.
If set to
'Repeated event'
the last stage will be
executed repeatedly until a reset occurs.
Delay
see Post Watchdog
Select the delay time before the runtime watchdog
becomes active. This ensures that an operating
system has enough time to load.
Event 1
NMI
ACPI Event
Reset
Power Button
Selects the type of event that will be generated when
timeout 1 is reached.
Event 2
Disabled
NMI
ACPI Event
Reset
Power Button
Selects the type of event that will be generated when
timeout 2 is reached.
Event 3
Disabled
NMI
ACPI Event
Reset
Power Button
Selects the type of event that will be generated when
timeout 3 is reached.
Summary of Contents for COM 830
Page 1: ...COM 830 Computer On Module Reference Manual P N 5001829A Revision A ...
Page 10: ...Chapter 1 About This Manual 4 Reference Manual COM 830 ...
Page 90: ...Chapter 4 BIOS Setup Description 84 Reference Manual COM 830 ...
Page 92: ...Appendix A Technical Support 86 Reference Manual COM 830 ...