10.3 Technical data Temposonics
®
RFV
Temposonics
®
R-Series
V
POWERLINK
Operation Manual
I 58 I
Output
Interface
Ethernet POWERLINK
Data protocol
POWERLINK V2
Measured value
Position, velocity/option: Simultaneous multi-position and multi-velocity measurements up to 30 magnets
Measurement parameters
Resolution: Position
0.5…100 µm (selectable)
Cycle time
Stroke length
≤ 715 mm
≤ 2000 mm
≤ 4675 mm
≤ 10,000 mm
≤ 20,000 mm
Cycle time
500 µs
8
1000 µs
2000 µs
4000 µs
8000 µs
Linearity deviation
9
Stroke length
≤ 500 mm
> 500 mm
Linearity deviation
≤ ±50 µm
< 0.01 % F.S.
Repeatability
< ±0.001 % F.S. (minimum ±2.5 μm) typical
Hysteresis
< 4 µm typical
Temperature coefficient
< 15 ppm/K typical
Operating conditions
Operating temperature
−40…+85 °C (−40…+185 °F)
Humidity
90 % relative humidity, no condensation
Ingress protection
IP30 (IP65 rating only for professional mounted guide pipe IP65 & if mating connectors are correctly fitted)
Shock test
100 g/6 ms, IEC standard 60068-2-27
Vibration test
5 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test
Electromagnetic emission according to EN 61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The RFV sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 No. 1091 and TR CU
020/2011 under the condition of an EMC-compliant installation.
10
Magnet movement velocity Any
Design/Material
Sensor electronics housing Aluminum (painted), zinc die cast
Sensor flange
Stainless steel 1.4305 (AISI 303)
Sensor rod
Stainless steel conduct with PTFE coating
RoHS compliance
The used materials are compliant with the requirements of EU directive 2011/65/EU and
EU regulation 2015/863 as well as UKSI 2022 No. 622
Stroke length
150…20,000 mm (6…787 in.)
Mechanical mounting
Mounting position
Any
Mounting instruction
Please consult the technical drawings on
Electrical connection
Connection type
2 × M12 female connectors (D-coded), 1 × M8 male connector or
2 × M12 female connectors (D-coded), 1 × M12 male connector (A-coded)
Operating voltage
+12…30 VDC ±20 % (9.6…36 VDC)
Power consumption
Less than 4 W typical
Dielectric strength
500 VDC (DC ground to machine ground)
Polarity protection
Up to −36 VDC
Overvoltage protection
Up to 36 VDC
8/
Minimum cycle time for multi-position measurements (number of magnets ≥ 2): 400 µs
9/
With position magnet # 251 416-2
10/
The flexible sensor element must be mounted in an appropriately shielded environment.