Amphenol PROTIMETER HygroMaster-L BLD7750L Instruction Manual Download Page 6

6 | INS7751 Rev. A

Note: The battery status is indicated by an icon on the
display. When the low battery message appears, replace
the battery.

To switch ON, Press the power button

momentarily.

Note: The HygroMaster-L switches OFF automatically
after a set time (can be set till 6 min) if no activity is
observed. (see instruction for setting the Auto OFF time)

To switch the instrument OFF immediately, press

and

hold for at least 3 seconds and release.

Whenever the battery voltage falls below the threshold value,
the battery symbol starts blinking. If the battery voltage falls
below the operating level, the instrument prompts with the
message “low battery - Switching off the device” and turns
OFF automatically.

There are three values displayed on the measurement
screen. First display value is the primary value which is the
relative humidity. Second display is Ambient temperature
and the third can be switched between dew point and mixing
ratio. Third measurement can be changed according to the
need of the customer using

or

key.

The representations in the measurement mode is as in the
picture on the page 7.

5. “ HygroMaster-L” modes

The Protimeter HygroMaster-L primarily measures air
temperature and relative humidity.

5.1 Measurement mode:

The default mode while the device is turned ON is
measurement mode. The device will turn ON with the
measurement screen as below.

Summary of Contents for PROTIMETER HygroMaster-L BLD7750L

Page 1: ...PROTIMETER HygroMaster L BLD7750L and BLD7751L Instruction Manual INS7751_EN Rev C March 2019 Amphenol Advanced Sensors...

Page 2: ...2 INS7751 Rev A...

Page 3: ...nt 7 5 2 3 Changing brightness 8 5 2 4 Setting Auto Off time 8 5 2 5 Buzzer ON OFF 8 5 2 6 Calibration 8 5 2 7 About 8 6 Care and maintenance 9 7 Technical Specifications 9 7 1 Operating Conditions 9...

Page 4: ...elect parameter save option in settings screen 2 Settings Key Any time the user wishes to setup the device can press this key to go to settings menu 3 Up Key Down Key a To navigate between Dew point a...

Page 5: ...ttery replacement Use same speci cation battery or as recommended when replaced 3 Product components and accessories Protimeter HygroMaster L uses analog or digital sensors to measure RH and temperatu...

Page 6: ...perating level the instrument prompts with the message low battery Switching off the device and turns OFF automatically There are three values displayed on the measurement screen First display value i...

Page 7: ...then the function parameter can be selected by scrolling through the menu using or and then pressing 5 2 1 Changing Language In the settings menu select LANGUAGE by navigating with or key Press to sel...

Page 8: ...et in to the edit mode as mentioned earlier and then use or key to change the Auto OFF time 5 2 5 Buzzer ON OFF User can set the buzzer ON of OFF based on the need If the user need an audible indicati...

Page 9: ...is to be stored for more than four weeks or if the low battery power symbol appears on the display remove the battery from the instrument 7 Technical Specifications 7 1 Operating Conditions Temperatur...

Page 10: ...0 6 F 0 3 C 7 3 Physical specifications 7 3 a Power Battery 9V Alkaline 550mAH Battery life visual indication on display 7 3 b Size HXWXD 6 9 in X 3 2 in X 1 5 in 17 7 cm X 8 0 cm X 3 8 cm 7 3 c Gross...

Page 11: ...Protimeter HygroMaster L 11 Notes...

Page 12: ...T 1 814 834 9140 U K Amphenol Thermometrics U K Limited Crown Industrial Estate Priorswood Road Taunton TA2 8QY UK T 44 1823 335 200 www protimeter com www amphenol sensors com 2019 Amphenol Thermomet...

Reviews: