4.用六角刀具把铜套压紧,压紧后铜套的抗拉拔力不少于50N

Crimp

 

copper

 

ferrule

 

with

 

hexagonal

 

crimping

 

tool,

 

the

 

minimum

 

retention

 

strength

 

is

 

50N

 

after

 

crimping.

5.套上端子然后压紧,压紧后端子抗拉拔力不少于下表中数值。

Place

 

terminal

 

onto

 

wire

 

and

 

crimp, the

 

minimum

 

tensile

 

strength

 

after

 

crimping

 

required

 

is

 

as

 

shown

 

in

 

the

 

list

 

below.

线缆规格 Cable Size

拉拔力Min tensile strength

2.5mm²or14AWG

222.5N

4mm²or12AWG

311.5N

6.将压好端子的电线(两条)插入连接器。

Insert

 

cable

 

with

 

crimped

 

terminal

 

into

 

connector.

 

Repeat

 

for

 

2

nd

cable.

7.完成组装。

Complete

 

Cable

 

Harness.

PL

02AI

002

  

Rev

 

2

PowerLok4.0

   

2

芯 组装式插头安装规范

PowerLok4.0

   

2

 

Pos Connector

 

Assembly

 

SPEC

Reviews: