5.2.1  Rear view PRO-ARU4G 

 
 
 
 
 
 
 
 
 
 

5.2.2  Rear view PRO-ARU8G 

 
 
 
 
 
 
 
 
 

5.3 

Connection of power supply voltage 

 

5.3.1  Mains connection 

The PRO-ARU…G is provided with a 3-terminal IEC60320-1 C14 (male) inlet for  
mains power connection.  The mains inlet is located on the rear side. See rear view above. 
Applied mains voltage must be within the range 207 – 264 VAC (230 – 240 V ±10 %). 
 
A 3-wire IEC power cord must be used for mains voltage connection. 
  

5.3.2  Protective earth 

The main earthing point is the center contact of the mains power inlet.  
See PRO-ARU…G rear view above. 
 
Connection to protective earth is provided via the 3-wire IEC power cord. 

The PRO-ARU…G therefore must be connected to an earthed mains socket-outlet. 

 

5.3.3  DC power connection  

The PRO-ARU…G is provided with a 3 pole screw terminal block (DC inlet)  
for connection of 12 VDC voltage or 24 VDC voltage (depending on model). 
The terminal block is located on the rear side. See rear view above. 
Applied DC voltage must be within the range 10.8 – 14.4 VDC (12 VDC model) 
or 18 – 28 VDC (24 VDC model). 
 
On the top plate next to the screw terminal block are indicated the polarity of the  
screw terminals:    
 
DC supply voltage (if used) must be applied correctly to the receiver multicoupler. 
If the polarisation of the applied DC voltage is wrong, the DC fuse will blow.  
The fuse must be replaced by a fuse according to chapter 7.1: “Spare parts”. 

+         – 

 

 

+

          

 

 

 

(Protective 

earth) 

ANT 

RX1      RX2      RX3     RX4     RX5     RX6      RX7    RX8 

DC 

fuse 

Mains 

fuse 

12 VDC 

or 

24 VDC 

inlet 

Mains 

power inlet 

(Equipotential 

bonding) 

 

+

          

 

 

 

(Protective 

earth) 

ANT 

RX1      RX2      RX3     RX4 

DC 

fuse 

Mains 

fuse 

12 VDC 

or 

24 VDC 

inlet 

Mains 

power inlet 

(Equipotential 

bonding) 

Summary of Contents for PRO-ARU4G

Page 1: ...19 Rack mountable Active Receiver Multicoupler type PRO ARU4G PRO ARU8G User Manual...

Page 2: ...1r1 Document Change Record Issue Date Sheet s Description of change Alterations endorsed and 1r0 05 10 2016 All First release SMN 1r1 09 07 2018 All New brand JF Procom Contacts Adnan Ahmad Director o...

Page 3: ...tion 6 5 1 Front view 6 5 2 Rear view 6 5 2 1 Rear view PRO ARU4G 7 5 2 2 Rear view PRO ARU8G 7 5 3 Connection of power supply voltage 7 5 3 1 Mains connection 7 5 3 2 Protective earth 7 5 3 3 DC powe...

Page 4: ...s in a system are connected to an equipotential bonding system The center terminal of the 3 pole screw terminal block on the rear side is intended for equipotential bonding See chapter 5 4 2 4 Fuses I...

Page 5: ...multicouplers can also be used for buffering and splitting any other kind of RF signal within the specified signal dynamic range of the equipment 4 Circuit description 4 1 Amplifier splitter modules...

Page 6: ...f If the mains voltage fails the multicoupler will automatically switch over to operate on the DC voltage thus providing an uninterrupted service The multicoupler can also operate directly on the DC v...

Page 7: ...power connection The PRO ARU G is provided with a 3 pole screw terminal block DC inlet for connection of 12 VDC voltage or 24 VDC voltage depending on model The terminal block is located on the rear...

Page 8: ...4 or RX1 to 8 depending on model on the rear edge of the receiver multicoupler top plate If the receiver multicoupler has unused RX output ports these should be terminated with a 50 dummy load min 250...

Page 9: ...com Symptom Possible cause Action Power on LED off Supply voltage not connected or off Connect supply voltage By DC voltage operation wrong DC polarity Check DC voltage and polarity and reverse connec...

Page 10: ...Page 10 of 10 9 Block Diagrams 9 1 Block diagram PRO ARU4G 9 2 Block diagram PRO ARU8G...

Reviews: