PAGE 2
PARTS IDENTIFICATIONS
1. GOOSENECK MICROPHONE
The illuminated gooseneck microphone can be detached from the console for safekeeping. Its
cardioid back electret capsule is sensitive to front voice pick up and reject rear unwanted
noise.
2. ZONE SELECT SWITCHES
12 individual zone selection switches are available for PM1120 and 6 for PM1060. LED
indicator is provided for active zone.
3. ALL CALL SWITCH
ALL CALL switch shall activate all zones with single press. Please note that a ALL CALL
signal is transmitted at the D connector.
4. CHIME / TALK SWITCH
Pressing this switch shall send signal for zones activated and followed by 4 tone upward
chime. Blinking LED indicates that the chime is being transmitted and still LED is to alert the
user that the microphone is ready for announcement.
Pressing momentary the switch shall deactivate the console in which a 4 tone downward
chime shall be broadcasted before shutting down the zone selection.
5. DATA CONNECTOR
The 15 pin D connector is used to send signal for zone selection, power supply and override
signal.
D male connector is supplied with every unit of PM series of microphones.
6. MICROPHONE LEVEL CONTROL
It is used to adjust the level of microphone gain.
7. CHIME LEVEL CONTROL
It is used to adjust the level of chime signal.
8. OUTPUT JACK
The output signal is balanced at 0 dB max, connection using stereo 1/4" phone jack.