background image

PAGE 2

PARTS IDENTIFICATIONS

1.  GOOSENECK MICROPHONE

The illuminated gooseneck microphone can be detached from the console for safekeeping. Its 

cardioid  back  electret  capsule  is  sensitive  to  front  voice  pick  up  and  reject  rear  unwanted 

noise.

2.  ZONE SELECT SWITCHES

12  individual  zone  selection  switches  are  available  for  PM1120  and  6  for  PM1060.  LED 

indicator is provided for active zone.

3.  ALL CALL SWITCH

ALL  CALL  switch  shall  activate  all  zones  with  single  press.    Please  note  that  a ALL  CALL 

signal is transmitted at the D connector.

4.  CHIME / TALK SWITCH

Pressing  this  switch  shall  send  signal  for  zones  activated  and  followed  by  4  tone  upward 

chime. Blinking LED indicates that the chime is being transmitted and still LED is to alert the 

user that the microphone is ready for announcement.

Pressing  momentary  the  switch  shall  deactivate  the  console  in  which  a  4  tone  downward 

chime shall be broadcasted before shutting down the zone selection.

5.  DATA CONNECTOR

The 15 pin D connector is used to send signal for zone selection, power supply and override 

signal. 

D male connector is supplied with every unit of PM series of microphones.

6. MICROPHONE LEVEL CONTROL

It is used to adjust the level of microphone gain.

7.  CHIME LEVEL CONTROL

It is used to adjust the level of chime signal.

8.  OUTPUT JACK

The output signal is balanced at 0 dB max, connection using stereo 1/4" phone jack.

Summary of Contents for PM 1060

Page 1: ...hall form a system with remote paging with zone selection capability Their balanced output allows long distance audio transmission ideal for professional requirement without having to spend extra Though it is rather simple in the installation works a brief read through the manual is recommended and we are confident that you are getting a product of excellence instruction manual version 1 04 PM 106...

Page 2: ...signal for zones activated and followed by 4 tone upward chime Blinking LED indicates that the chime is being transmitted and still LED is to alert the user that the microphone is ready for announcement Pressing momentary the switch shall deactivate the console in which a 4 tone downward chime shall be broadcasted before shutting down the zone selection 5 DATA CONNECTOR The 15 pin D connector is u...

Page 3: ...PAGE 3 PARTS IDENTIFICATIONS TOP VIEW REAR VIEW 3 4 2 1 5 8 7 6 ...

Page 4: ...0 9 core PM1120 15 core multi core cable 2 core screen for balance audio output NOTE The above diagram illustrates typical interconnections between PM paging microphone and with Amperes series of PA equipments Application of PM paging microphones are not limited to usage with other Amperes products only PM can be used alongside with almost any brand of PA equipments Kindly consult us if there is a...

Page 5: ...ion for zone selection for next paging PM1060 1120 and ZS5601 5121 When using PM1060 1120 with Amperes ZS5601 5121 activation of paging console shall automatically mute the BGM broadcast of the zones at the zone selector panel Upon deactivation of the paging mic the BGM broadcast shall resume of the preselected zones PM1060 1120 and ZS602 Unlike ZS5601 5121 activation of PM1060 1120 shall mute the...

Page 6: ...AMP 1 100V AMP 2 100V COM 100V ZON2 COM ZON4 100V ZON3 100V COM 100V AMP 4 COM AMP 5 100V COM ZON5 COM COM 100V REMOTE SELECT 8 ZON6 100V COM 7 COM 10 9 A 12 11 TO PAGING MIC CONNECTOR EXAMPLE 2 CONNECTION FOR VOLUME CONTROLLER OVERRIDE Sometimes the operator would like to override the volume controllers or the patch panels from the paging console by pressing ALL CALL while other zone activation i...

Page 7: ...ouncement to speaker zone can be selected from the paging console individually or ALL CALL PREANNOUNCEMENT CHIME 4 tone chime is broadcasted prior to mic activation and the same with downward chime when announcement is ended BGM MUTING When using the paging mic with Amperes series of zone selectors activation of the paging mic shall automatically mute the BGM zone at the zone panel The BGM broadca...

Page 8: ...n using the product This warranty certificate is valid only for the described product and is not valid if modifications are made on this certificate or on the identification label applied on the product This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from the date of purchase or for a longer period in countries where this is stated by a nation...

Reviews: