Amperes PD1280 Instruction Manual Download Page 3

amperes

PD1280 Digital Paging Microphone

PAGE 3

Parts Identification

1.  PAGING MICROPHONE INLET

XLR inlet for gooseneck microphone. Use only condenser microphone supplied or those operates under 3 to 9 V.

2.  LCD DISPLAY

Factory default display is with back light. User has the option to turn off. Please refer to setup section.

3.  GROUP RECALL

It is used for programming & recall zone grouping during G1 ~ G8 button.

4.  SIREN BUTTON

Press this siren button the LCD shall show the ‘Siren Active’, after that press the ‘Chime & Talk’ button shall activate 
the EP1200A to siren mode.

5.  ALL CALL BUTTON

Mic shall be activated instantly without chime, triggering all normal zones. Note that making ALL CALLs will not trigger
the overriding relay at the zone selectors, thus the volume controllers set at minimum shall not be overrided.

6.  F1 ~ F3 BUTTON

This button for future add-on other function.

7.  KEYPAD

Zone selections and programming are done via these keypad.

8.  REPEAT BUTTON

Press repeat button for recall previous zone selection.

9.  CHIME AND TALK BUTTON

Select the zones required before pressing this button. A chime shall start (if selected) and followed by mic activation, 
which is indicated by the illuminated ring at the microphone.

10. GOOSENECK MICROPHONE

This detachable condenser mic comes with illuminated ring when the mic is in active mode and ready for paging.

11. CHIME & MIC VOLUME CONTROL

Individual volume for chime and microphone output level can be adjusted according to site requirement.

12.OUTPUT CONNECTION

Connet the RJ45 cable to EX2800 for power, data and audio. If the paging mic is located near the decoder at the rack
(within 50m), the cable can be connected directly to TD6240 / TD6080 / MxP2188 without using EX2800.

13. POWER SWITCH

Switch for 24V power to unit..

16. PAGING MIC CONNECTION (EX2800)

Connect to the paging mic via this RJ45 connector. For pin configuration, refer to the diagram.

14. DATA / AUDIO OUTPUT (EX2800)

Data and audio are linked to TD6240 decoder unit using 2 pair screen cable. Please refer to ‘ Connecting the Unit’ for 
detailed connection diagram.

15. DATA / AUDIO INPUT LINK / DC SUPPLY (EX2800)

Data and audio from other EX2800 (if any) are fed to this port forming a circuit. This connection is applicable only if
multipoint paging setup is establised. Use a DC24V power adaptor supplied for powering the unit.

Summary of Contents for PD1280

Page 1: ...re sure you make the right decision to choose Amperes which is not only offering the product that meets your budget but perform beyond your expectation We appreciate that you read through the manual t...

Page 2: ...ocessor Features available include priority level assignment multipoint paging setup chime and microphone volume controls as well as illuminated gooseneck microphone The search for contemporary design...

Page 3: ...quired before pressing this button A chime shall start if selected and followed by mic activation which is indicated by the illuminated ring at the microphone 10 GOOSENECK MICROPHONE This detachable c...

Page 4: ...restriction at the console Cat5e 2P Screen Triggering signal audio output balanced 100V Other complementary equipment may be required in the system such as EP1200 for Emergency Paging and overriding...

Page 5: ...T ADDRESS ETHERNET SUBNET ETHERNET GATEWAY amperes iPx 5100 MAC ADDRESS SERIAL NO RESET Quality Product From AMPERES ELECTRONICS Network Switch iPX5150 iP CLIENT iPX5100 iP SERVER BGM 2 MxP2188 MATRIX...

Page 6: ...ced signal 2 2 Use this switch to select the audio output level mic or line level when connecting to pre amplifier mixer Remote triggering using Cat5e multicore cable via RJ45 jack Cable provided 24V...

Page 7: ...Audio o p TD6240 ZONE DECODER MX2222 Pre Amp Mixer Speaker Zone Selector Speakers in Various Zones Power Amplifier Triggering signal 100V PIN 8 PR PIN 7 AC PIN 6 Z6 PIN 5 Z5 PIN 4 Z4 PIN 3 Z3 PIN 2 Z...

Page 8: ...280 PD1280 2 pair screen cable 2 pair screen cable 1 Data A 2 Data B 3 Audio ve 4 Audio ve 5 Screen Ground Cable Size shall be according to the distance from the paging mic and the equipment rack Conn...

Page 9: ...ection to MxP2188 if only one PD1280 and one Matrix is used Power directly from MxP2188 length do not exceed 50 m MS1103 to be used if more than one Matrix controller is installed An illustration of t...

Page 10: ...ready for paging Setup Menu 1 4 2 5 3 6 7 CLR 8 0 9 ADD F1 F2 F3 1 Press 0 button momentarily 3 seconds to enter Setup mode 2 Press Add button for next 3 Press CLR for Exit setup mode When using for t...

Page 11: ...enu press 0 button If no entry is made within 15 seconds the setup menu shall exit automatically and return to ready mode Setting priority level of the paging mic Setting the chime type for mic activa...

Page 12: ...is used in single point paging setup Maximum can set 10 level priority 2 CHIME 2 CHIME 2 1 1st Chime 2 1 1st Chime UP Press 0 to enter this sub menu from the main directory Press CLR Return to main me...

Page 13: ...o 4 ZONE SETTING 4 1 Max Zone 248 Press 0 for Enter Press ADD for Select Press 0 for Save T 4 ZONE SETTING Press 0 to enter this sub menu from the main direc tory This is to set the maximum number of...

Page 14: ...the main directory This is to set the maximum number of zones available in the system We recommend this setting to be done to enable faster response during paging Press 0 to enter this sub menu from t...

Page 15: ...XIT 10 SAVE AND EXIT NO Press 0 for Enter Press ADD to Select Yes No Press 0 for Enter Saving Group 1 Press 0 to enter this sub menu from the main directory To check the firmware version of the paging...

Page 16: ...llowed by a downward chime Example Performing a paging to zone 1 and 15 Press button 1 Press button ADD Press button 1 and 5 Press CHIME TALK Talk when the LED ring at the mic is lit and to end press...

Page 17: ...240 TD6080 4 tones up and 4 tone down Zones power audio data gooseneck ring LED LCD display white back illumination 100 12 kHz Appr 1 6kg 65 dB 1 KHz 230 x 192 x 65 mm Excluding Mic Operating voltage...

Page 18: ...windows should appear Diagram 2 3 At PD1280 press 0 button for select menu Select menu number 8 System Info and Select 8 2 update 4 Press 0 and enter for update 5 Load latest firmware by click New Fir...

Page 19: ...amperes PD1280 Digital Paging Microphone PAGE 19 Communication Ports Continue Diagram 4 Diagram 5 Diagram 3...

Page 20: ...valid only for the described product and is not valid if modifications are made on this certificate or on the identification label applied on the product This warranty covers all the material and man...

Reviews: