Amperes PA 2060 Instruction Manual Download Page 6

Page 6 

 PA2000 Series | Power Amplifier

Application example using one duty amplifier with one standby unit connecting to two zones of speakers.

SPEAKER ZONE 1

SPEAKER ZONE 2

ZS5602

ZONE SELECTOR

AC3601

MANUAL AMPLIFIER

CHANGEOVER

PA2480

POWER AMP AS

DUTY UNIT

PA2480

POWER AMP AS

STANDBY UNIT

MX2222

PRE-AMP MIXER

100V outputs looped to zone 2

Input to standby

input to duty

TO DC BACK UP 

DC back up supply

connected in 

parallel

line output

input signal parallel to 

next amplifier

AC MAINS

AC MAINS OR

FROM 

SQ9715

1 2 3

ZON6

5 6

4

24 V

( 3 WIRE SYSTEM ONLY )

AMP4

BGM AMPLIFIER INPUTS - NORMAL BGM OUTPUTS

ZON2

COM

100V

COM

100V

100V

COM

ZON1 AMP 2

COM

100V

100V

100V

COM

COM

AMP 3 ZON3

ZON5

COM

100V

100V

COM

COM

100V

AMP5

ZON4

100V

COM

COM

COM

100V

ZON6

AMP6

AMP 3

PAGING AMPLIFIER INPUTS - ZONE OUTPUTS

( OR 3 WIRE SYSTEM PRIORITY ZONE OUTPUTS )

ZON1

100V

COM

100V

AMP 1

100V

100V

COM

100V

COM

COM

ZON2

AMP 2

100V

AMP 1

PLEASE OBSERVE POLARITY WHEN CABLING

COM

AMP 6

COM

ZON4

COM

100V

COM

100V

100V

COM

ZON3 AMP 4

COM

100V

100V

100V

COM

AMP 5 ZON5

ZONE DC OUTPUTS

COM

100V

Unit Installation

Summary of Contents for PA 2060

Page 1: ...o its predecessor Every model in the series is now with 2 HU heights and would definitely be a great saving to the rack spaces They are available in power ratings of 120 to 480W 100V line With its enh...

Page 2: ...mming pool or the like 5 This product should be located so that its location or position does not interfere with its proper ventillation 6 This product should be located away from heat sources such as...

Page 3: ...amage the components Upon reaching a preset temperature the amplifier would enter protect mode which would let the unit idle until the excessive heat is dissipated The amplifier shall enter into prote...

Page 4: ...connection of back up 24V DC supply from batteries Two ports are available for parallel connections 5 SPEAKER OUTPUT Outgoing terminals to speakers are available in 4 Ohm 70 and 100V line for usage w...

Page 5: ...tput volume is adjustable from 15dB to 0 dB 7 VOLUME KNOB COOL AIR The above diagram depicts the air flow pattern for the amplifier cooling system Cool air intake is taken from outside via dual speed...

Page 6: ...put signal parallel to next amplifier AC MAINS AC MAINS OR FROM SQ9715 1 2 3 ZON6 5 6 4 24 V 3 WIRE SYSTEM ONLY AMP4 BGM AMPLIFIER INPUTS NORMAL BGM OUTPUTS ZON2 COM 100V COM 100V 100V COM ZON1 AMP 2...

Page 7: ...ER AS STANDBY PA2480 POWER AMPLIFIER AS DUTY UNIT MX2222 PRE AMP MIXER illustration shows application with an amplifier serving two zones of speakers Unit Installation DC 24V 0 5 A IN IN OUT IN IN OUT...

Page 8: ...P 5 ZON5 ZONE DC OUTPUTS COM 100V SPEAKER ZONE 2 SPEAKER ZONE 1 For 4 wire system only ZS5602 UNINTERRUPTED PAGING ZONE SELECTOR PA2480 POWER AMPLIFIER FOR PAGING PA2480 POWER AMPLIFIER FOR BGM MX2222...

Page 9: ...cuit can be obtained from our service department Earth Loop To avoid hum or noise to the output the chassis earth and the electrical earth should be separated this can be done by switching the Ground...

Page 10: ...ower requirement Power consumption 240V AC Current consumption 24V DC Standby current 24V DC Input signal Input gain controls Rated output 100V RMS 4 Ohm output voltage Output impedance max load Frequ...

Page 11: ...f repairs are performed by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and instal...

Page 12: ...ISO 9001 2008 Design Manufacture of Public Address Equipment and Systems Certificate No 16895 A 0001 UK En Made In Malaysia Updated October 2016...

Reviews: