Connecting Paging Microphone
PAGE 5
MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
External paging desk with or without zone selection can be connected to the unit, preferable with mic level output.
Connection can be done via the front panel 1/4" stereo phone jack or rear panel XLR jack. It is recommended that
paging desk with zone selection (Amperes PM1060) be connected via the rear panel jack.
The diagram below illustrates the connection of Amperes PM1060 paging desk with zone selection :
AMPERES PM1060 PAGING DESK
Rear View
MA2024:
}
Paging Mic
Audio Output
(2 Core Screen Cable)
6 Core
Cable
Remote Zone Control
& Power Supply
Connection :
PM1060 MA2012
Remote SP1
Remote SP2
Remote SP3
- 24V DC
Remote PR
+ 24V DC
Pin 1
Pin 2
Pin 3
Pin 13
Pin 14
Pin 15
WARNING !
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
CAUTION
CH3
CH5
CH6
CH4
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
CH3
CH4
CH5
CH6
MIC LEVEL (BALANCED/UNBALANCED)
LINE LEVEL
MIC LEVEL
CH.1 / 2 / EXT.IN
MAX
CH3
CH5
CH6
CH4
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
CH3
CH4
CH5
CH6
MIC LEVEL (BALANCED/UNBALANCED)
LINE LEVEL
PRIORITY MUTE
CH.1 / 2 / EXT.IN
MAX
Remotely Activate ALL CALL
WARNING !
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
CAUTION
To remotely trigger ALL CALL on MA2000 series mixer amps
from another device we can externally install a pair of diodes to
the AC ( ALL CALL ) and PR ( PRIORITY ) ports of the mixer
amp. The diodes are then connected to the dry contact of an
external device. In the left figure, the diodes are linked to
RELAY CONTACT of an Emergency Paging Panel, EP1200.
When the EP1200 siren / message trigger is activated, it will
activate ALL CALL on the mixer amp.