Parts Identification

2

PAGE 2

iPX5155 | ETHERNET BGM / PAGING CLIENT

3

6

7

1

Front View

Rear View

9

10

5

4

8

POWER - This blue LED shall lit when iPX5155 is powered On.

SERVER - This green LED shall lit when iPX5155 successfully establish a connection with Paging Server (iPX5101).

STATUS - Blink whenever there is a network activity ongoing.

STREAMING - Blink whenever iPX5155 is transmitting / receiving streaming audio to / from another paging client or music server

1.  INDICATOR LEDS

24V DC power supply input.

2.  POWER PORT

Ethernet port for connecting to network switch.

3.  ETHERNET PORT

Button to allow iPX5155 enters Bootloader mode or reset settings to factory default settings. 
Bootloader  mode:  To  enter  this  mode,  hold  the  reset  button  until  POWER,  SERVER  and  STATUS  LEDs  lit.  Enter  this      
mode to do firmware updating if normal mode updating does not work. All iPX5155 settings remain intact in this mode.
Reset  to  factory  default  settings:  Hold  the  reset  button  until  POWER,  SERVER,  STATUS  and  STREAMING  LEDs  lit 
will reset all iPX5155 settings to factory default settings.

4.  RESET BUTTON

This  port  provides  a  dry  contact  which  can  be  used  to  connect  E/M  overriding  signal  or  activate  ALL  CALL  at    

speaker zone selector.

5.  RELAY CONTACT

We can activate iPX5155 paging using voltage free dry contact. Connecting PM series paging mic / MR1301 message recorder / 
TI6100 Telephone Interface dry contact to this port will activate iPX5155 and have their analog audio signal stream to the network. 
This port only work when iPX5155 operates in Input mode. (refer page 7) 

6.  REMOTE TRIGGER PORT

For data transmission (RS485) among iPX5155, PD paging mic and zone decoder like TD6240 / TD6400 / TD6080. 

7.  RS485 PORT

This LED shall blink according to the rhythm of the input paging mic audio.

8.  SIGNAL INDICATOR

Connect paging mic or other audio source analog audio signal to this port. The signal shall be in balanced line level.

9.  AUDIO INPUT PORT

iPX5155 broadcast analog audio signal via this port to mixer or amplifier. The signal is in balanced line level.

10. AUDIO OUTPUT PORT

Summary of Contents for iPX5155

Page 1: ... broadcast from central system such as from iPX5200 audio music server or PMX software and deliver balanced audio output to amplifiers Upon Paging broadcast and intended for the particular address of iPX5155 the BGM shall be muted and resume when Paging ends UART RS485 is available for controls of zone selection if required With iPX5000 series of LAN paging equipment new setup for large and decent...

Page 2: ...ttings Hold the reset button until POWER SERVER STATUS and STREAMING LEDs lit will reset all iPX5155 settings to factory default settings 4 RESET BUTTON This port provides a dry contact which can be used to connect E M overriding signal or activate ALL CALL at speaker zone selector 5 RELAY CONTACT We can activate iPX5155 paging using voltage free dry contact Connecting PM series paging mic MR1301 ...

Page 3: ...available to all switchers LOCAL PA EQUIPMENT INCL PRE AMPLIFIER MIXER ZONE DECODER POWER AMPLIFIERS ETC NETWORK SWITCH WITH FIBER LINK SUB RACK MAIN RACK Note In a system only one iPX5101 is required no matter what the size of the system or the number of clients iPX5151 iPX5155 are installed EP 1200 amperes EMERGENCY PAGING PANEL MIC SIREN SWITCH SIREN FIRE EMERGENCY SIREN ACTIVE Paging Audio Dat...

Page 4: ...TROLLER NETWORK SWITCH LOCAL PA EQUIPMENT INCL PRE AMPLIFIER MIXER ZONE DECODER POWER AMPLIFIERS ETC Paging Music Siren Data PC with PMX LAN Software Paging Music Siren iPX5155 can work with iPX5101 and PMX LAN to allow a user to conduct paging music playing or initiate a siren from a PC cat5e cat5e iPX5155 Output Mode cat5e ...

Page 5: ...20 Paging Music Client MAC Address IP Address Subnet Mask Gateway Address Data Port 114 106 118 28 6 29 192 168 0 155 255 255 255 0 192 168 0 1 3000 Server Name Server IP Server Version Blk A Paging Server 192 168 0 101 2 29 Server Name Server IP Server Version Blk A Music Server 192 168 0 120 2 07 Device Information Network Information Paging Server Status Music Server Status Network Configuratio...

Page 6: ...cally or turn Off the setting and specify the Paging Server IP address here Note If Paging Server IP address is changed to an unknown value turn On the Auto Connect allow auto capture the server IP address and show up in the device information page Input Mode Settings Output Mode Settings Paging Enabled Auto Connect Operating Mode Start Zone End Zone Restricted Zones Dry Contact Any Paging Input O...

Page 7: ...paging or send the RS485 data to activate zone decoder channels Below are settings that available in Output mode Start End Zone This is iPX5155 serving zone range Whenever paging zones that fall within this zone range but excluded in the Restricted Zones see below were called the iPX5155 shall output the paging audio and activate the corresponding channels on zone decoder Restricted Zones Zone s t...

Page 8: ...ting shall allow us to configure level 1 to 12 The lower the number the higher the priority level All Call Enable this setting to page to all zones when the iPX5155 Remote Trigger port get activated Disable this setting shall allow us to configure a zone range Auto Override Low Priority AOLP Enable this setting shall allow a paging mic that connected to this iPX5155 Remote Trigger port to override...

Page 9: ...dress here Note If Server IP address is changed to an unknown value turn On the Auto Connect allow auto capture the server IP address and show up in the device information page Audio Configuration To adjust volume and EQ of music audio Audio Configuration BGM Server IPX5200 PMX Volume 5 Band Equalizer 80 0dB 0dB 0dB 0dB 0dB 100Hz 250Hz 1KHz 4KHz 10KHz BGM Enabled Auto Connect Device Name Paging Mu...

Page 10: ... the IP address 192 168 0 100 A web page as shown below shall appear 3 Select Upload Firmware choose a binary file with acfr extension and click UPLOAD 4 Once the uploading is completed the browser shall enter the login page Update firmware in Bootloader Mode If the iPX5155 hanged it is required to perform system reset by Click the Upload Firmware button to find the updated firmware file Find the ...

Page 11: ...ing encoding User interface Firmware upgrade Operating condition Temperature Humidity Case Dimension WxHxD Weight 18 24V DC Normal DC 24V 60 mA 1 5W RJ45 10 100 Base T TCP IP UDP HTTP IGMP ADMP 3 2Vrms 2 8Vrms with Analog in 3 2Vrms 90 Ohm 100 pF 0 1 83 dB G 722 Google Chrome MS Edge IE V8 Via Web Browser 20 C 80 C 0 70 100 x 147 x 40 mm 300 g Note The above specifications are correct at time of p...

Page 12: ...erformed by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the product from the main system are for the account of the purchaser This warranty shall not extend to the replacement of the unit This warranty does not cover damages caused by misuse neglect accident of...

Reviews: