4
1
Ampac
7 Ledgar Road, Balcatta, Western Australia 6021
Telephone: +618 9201 6100 Fax: +618 9201 6101
Email: [email protected] Website: www.Ampac.net
XP95 Base VAD and Sounder VAD
Installation Guide
General
This guide describes the installation of the following base variants
Item Number
Product Description
Category
4107-6002
XP95 Base Sounder VAD Cat O (AS7240-3 & 23)
O
4107-2007
XP95 Base VAD Cat O (AS7240-23)
O
201-114
White Cap only (Lockable)
N/A
201-119
Red Cap only (Lockable)
N/A
Connect the devices only to control panels using the XP95 protocol.
The XP95 Base Sounder VADs combine a sounder with a visual alarm and a detector base in one unit.
The VAD is activated whenever the sounder is active and cannot be controlled separately.
All XP95 Base VAD and Sounder VAD variants with short circuit isolator have a yellow LED which illuminates
through the moulding if a short circuit is detected on the loop wiring (see Fig. 1).
Note: All
XP95 Base VAD and Sounder VAD
variants are not suitable for outdoor use.
Mounting Instructions
All base variants may be secured to a UK standard conduit box or surface mounted (providing there is
access through the surface for cabling). If a detector is
fi
tted, lock it if required by screwing in the grub
screw in the detector with a 1.5mm hex driver. The XP95 Sounder VAD Bases are ceiling mounted devices.
For coverage volume information please refer to PDS4107-6002 and PDS4107-2007
Wiring Details
Note: These products are polarity sensitive (supply reversal protected) and will not function if wired
incorrectly.
Terminate all loop cables in the two way terminal blocks. Connect the incoming loop cables to L1 IN (–)
and L2 (+) and the outgoing cables to L1 OUT (–) and L2 (+). Functional earth or screen may be connected
to the EARTH connection. The isolator LED can be seen through the moulding as shown in Fig. 1.
DO NOT CONNECT LOOP CABLES TO THE OUTER TERMINALS OF ISOLATED MODELS.
When using as a stand-alone unit, a cap is available (red cap Part No 201-119 or white cap Part No 201-114)
and is secured with a 1.5mm, AF hexagon socket head screw.
39215-212/Issue 1
Technical Data
Operating Voltage
17—28V dc
Sounder Output
High Tone Setting Volume
nominally 71dB(A) to 88dB(A)*
Low Tone Setting Volume
nominally 58dB(A) to 73dB(A)
*Complies with AS7240-3
Sound pressure level information published in document PDS4107-6002 and isolator operation information
published in document PDS201-9001, both available on request. Low volume setting does not comply to
AS7240-3 and should not be used for
fi
re alarm applications.
Current Consumption at 24V dc
Quiescent
350
μ
A
Switch-on
Surge
1.2mA for 1 sec
Sounder/VAD
Operating
14mA
VAD
Frequency
0.5Hz
IP
Rating
IP21C
XPERT Card Addressing
Select the desired address and remove the pips indicated in black. Remove pips with a small screwdriver.
Tone Table
1
2
4
8
16
32
64
1
1
1
2
4
8
16
32
64
10
10
1
2
4
8
16
32
64
9
9
1
2
4
8
16
32
64
8
8
1
2
4
8
16
32
64
7
7
1
2
4
8
16
32
64
6
6
1
2
4
8
16
32
64
5
5
1
2
4
8
16
32
64
4
4
1
2
4
8
16
32
64
3
3
1
2
4
8
16
32
64
2
2
1
2
4
8
16
32
64
11
11
1
2
4
8
16
32
64
20
20
1
2
4
8
16
32
64
19
19
1
2
4
8
16
32
64
18
18
1
2
4
8
16
32
64
17
17
1
2
4
8
16
32
64
16
16
1
2
4
8
16
32
64
15
15
1
2
4
8
16
32
64
14
14
1
2
4
8
16
32
64
13
13
1
2
4
8
16
32
64
12
12
1
2
4
8
16
32
64
21
21
1
2
4
8
16
32
64
30
30
1
2
4
8
16
32
64
29
29
1
2
4
8
16
32
64
28
28
1
2
4
8
16
32
64
27
27
1
2
4
8
16
32
64
26
26
1
2
4
8
16
32
64
25
25
1
2
4
8
16
32
64
24
24
1
2
4
8
16
32
64
23
23
1
2
4
8
16
32
64
22
22
1
2
4
8
16
32
64
31
31
1
2
4
8
16
32
64
40
40
1
2
4
8
16
32
64
39
39
1
2
4
8
16
32
64
38
38
1
2
4
8
16
32
64
37
37
1
2
4
8
16
32
64
36
36
1
2
4
8
16
32
64
35
35
1
2
4
8
16
32
64
34
34
1
2
4
8
16
32
64
33
33
1
2
4
8
16
32
64
32
32
1
2
4
8
16
32
64
41
41
1
2
4
8
16
32
64
50
50
1
2
4
8
16
32
64
49
49
1
2
4
8
16
32
64
48
48
1
2
4
8
16
32
64
47
47
1
2
4
8
16
32
64
46
46
1
2
4
8
16
32
64
45
45
1
2
4
8
16
32
64
44
44
1
2
4
8
16
32
64
43
43
1
2
4
8
16
32
64
42
42
1
2
4
8
16
32
64
51
51
1
2
4
8
16
32
64
60
60
1
2
4
8
16
32
64
59
59
1
2
4
8
16
32
64
58
58
1
2
4
8
16
32
64
57
57
1
2
4
8
16
32
64
56
56
1
2
4
8
16
32
64
55
55
1
2
4
8
16
32
64
54
54
1
2
4
8
16
32
64
53
53
1
2
4
8
16
32
64
52
52
1
2
4
8
16
32
64
63
63
1
2
4
8
16
32
64
62
62
1
2
4
8
16
32
64
61
61
1
2
4
8
16
32
64
124
124
1
2
4
8
16
32
64
126
126
1
2
4
8
16
32
64
125
125
1
2
4
8
16
32
64
80
80
1
2
4
8
16
32
64
79
79
1
2
4
8
16
32
64
78
78
1
2
4
8
16
32
64
77
77
1
2
4
8
16
32
64
76
76
1
2
4
8
16
32
64
70
70
1
2
4
8
16
32
64
69
69
1
2
4
8
16
32
64
68
68
1
2
4
8
16
32
64
67
67
1
2
4
8
16
32
64
66
66
1
2
4
8
16
32
64
65
65
1
2
4
8
16
32
64
64
64
1
2
4
8
16
32
64
71
71
1
2
4
8
16
32
64
75
75
1
2
4
8
16
32
64
74
74
1
2
4
8
16
32
64
73
73
1
2
4
8
16
32
64
72
72
1
2
4
8
16
32
64
81
81
1
2
4
8
16
32
64
90
90
1
2
4
8
16
32
64
89
89
1
2
4
8
16
32
64
88
88
1
2
4
8
16
32
64
87
87
1
2
4
8
16
32
64
86
86
1
2
4
8
16
32
64
85
85
1
2
4
8
16
32
64
84
84
1
2
4
8
16
32
64
83
83
1
2
4
8
16
32
64
82
82
1
2
4
8
16
32
64
91
91
1
2
4
8
16
32
64
100
100
1
2
4
8
16
32
64
99
99
1
2
4
8
16
32
64
98
98
1
2
4
8
16
32
64
97
97
1
2
4
8
16
32
64
96
96
1
2
4
8
16
32
64
95
95
1
2
4
8
16
32
64
94
94
1
2
4
8
16
32
64
93
93
1
2
4
8
16
32
64
92
92
1
2
4
8
16
32
64
101
101
1
2
4
8
16
32
64
110
110
1
2
4
8
16
32
64
109
109
1
2
4
8
16
32
64
108
108
1
2
4
8
16
32
64
107
107
1
2
4
8
16
32
64
106
106
1
2
4
8
16
32
64
105
105
1
2
4
8
16
32
64
104
104
1
2
4
8
16
32
64
103
103
1
2
4
8
16
32
64
102
102
1
2
4
8
16
32
64
111
111
1
2
4
8
16
32
64
120
120
1
2
4
8
16
32
64
119
119
1
2
4
8
16
32
64
118
118
1
2
4
8
16
32
64
117
117
1
2
4
8
16
32
64
116
116
1
2
4
8
16
32
64
115
115
1
2
4
8
16
32
64
114
114
1
2
4
8
16
32
64
113
113
1
2
4
8
16
32
64
112
112
1
2
4
8
16
32
64
123
123
1
2
4
8
16
32
64
122
122
1
2
4
8
16
32
64
121
121
Item Number
Primary Tone
Secondary Tone
4107-6002
Australian AS7240-3 Evacuation Tone
Australian AS7240-3 Alert Tone