FireFinder

 

Liquid Crystal Display Repeater

 

 

 

2.3  The Main Menu 

 

 

Figure 4: The Main Menu 

Press the forward, back, up or down keys to navigate the cursor or highlighted selection to the required 
menu. In the MENU the user can view; 

0

  

FIRE ALARMS:

 

1

  

PRE-ALARMS:

 

2  

SYSTEM STATUS: 

Press Menu to enter the STATUS MENU. 

 

 

Figure 5: The Status Menu 

From the STATUS MENU the status of all of the system components and settings listed below can be 
displayed. 
 

3

  

FAULTS:

 Pressing

 Menu 

brings up a sub-menu from which a more detailed description of 

the Defect can be displayed. With a Defect present use the navigation keys to select the required field 
then press menu to select the field ( 0 to 4 ).  

 

 

Zones 

Devices

 

Œ

 

Loops 

 

Modules

 

Ž

 

Power 

Supply

 

 

Brigade

 

 

Zones Devices: 

Display identified zone and device faults 

 

Œ

 

Loops:

 Display identified loop  faults 

 

 

Modules: 

Display loop and I/O module faults. 

 

Ž

 

Supply:

 

This menu item will display the charger voltage, whether or not the power 

supply is in fault, if the battery is correctly fitted and if Mains power is present. 

 

 

Brigade:

 

This displays the  fault status of all of the monitored  outputs on the Brigade 

Board. Eg. Bell, Aux, DSW, Warn, Fault, Alarm, Isol, Bfail, Vmon & Brigade Status. 

 

4

  

ISOLATES:

  Selecting ( pressing Menu ) on the system.

 

 

5  

PRINTER RESET: 

Selecting ( pressing Menu ) resets the printer ( empties the buffer ).

 

 

RETURN: 

Selecting ( pressing Menu ) returns the user to the Default screen

 

MAIN MENU 
0: ALARMS  

1 :PRE-ALARM  

    2: SYS- STATUS   

3: FAULTS 

4: ISOLATES  

5: PRINTER RESET  

5 :RETURN 

SELECT No. 
 
 
 
AL:1S      ALM: 000   

PALM: 000    

 FLT: 000  

ISOL: 000 

SYSTEM STATUS 
0: ALARMS 0000      

1 :PRE-ALARMS 0000 

 2:ISOLATES 0000 

3: DEVICE FAULTS 0000 

4: MOD FAULTS 00 

5: LOOP FAULTS   

 

 

 

VERSION: NZS4512 

 
 
 
AL:1S      ALM: 000   

PALM: 000    

 FLT: 000  

ISOL: 000 

 

Summary of Contents for FireFinder NZS 4512

Page 1: ...4 45 5 51 1 12 2 2 L L Li i iq q qu u ui i id d d C C Cr r ry y ys s st t ta a al l l D D Di i is s sp p pl l la a ay y y R R Re e ep p pe e ea a at t te e er r r Our aim is to provide Consistently Excellent Service in the eyes of our customers User s Manual ...

Page 2: ......

Page 3: ...er Liquid Crystal Display Repeater Table Of Contents Page No 1 Liquid CrystalDisplay Repeater 1 1 1 Programmable Switches 1 2 Operation 2 2 1 The Default LCD Display 3 2 2 Accessing Menus 3 2 3 The Main Menu 4 ...

Page 4: ...FireFinder Liquid Crystal Display Repeater ...

Page 5: ...mmed as Acknowledge Reset Sounder or External Bell Silence The keys will have the following operational characteristics if programmed as Acknowledge Pressing this key will acknowledge an alarm currently displayed on the LCD It will also silence the panel buzzer which sounds whenever there is an alarm optional or fault Reset Pressing this key will reset the FACP clearing any acknowledged alarms and...

Page 6: ...aults device faults etc 4 ISOLATE Yellow This LED will light steady if any detectors devices or zones in the system have been isolated 5 PRE ALARM Red This LED will flash if any unacknowledged Pre alarms are present on the system If all the Pre alarms have been acknowledged it will light steady 6 PREVIOUS Previous is used for scrolling backwards through the displayed system status alarms faults or...

Page 7: ...igured via the FACP with the servicing companies name and phone number It also displays the current date time and that the system is normal If there are any faults or alarms the LCD will display the device in question if multiple detectors or zones are not in their normal state the PREVIOUS and NEXT keys are used to scroll through them 2 1 The Default LCD Display In its normal state the LCD will d...

Page 8: ...identified zone and device faults Œ Loops Display identified loop faults Modules Display loop and I O module faults Ž Supply This menu item will display the charger voltage whether or not the power supply is in fault if the battery is correctly fitted and if Mains power is present Brigade This displays the fault status of all of the monitored outputs on the Brigade Board Eg Bell Aux DSW Warn Fault...

Page 9: ......

Page 10: ... Australia Tel 61 8 9242 3333 Fax 61 8 9242 3334 Email info ampac net EUROPE AMPAC EUROPE LTD Unit 18 Network centre Yorkshire Way West Moor Park Doncaster England DN3 3GW Tel 44 0 1302 833 522 Fax 44 0 1302 835 021 Email info eu ampac net NEW ZEALAND AMPAC PACIFIC LTD Unit 4 101 Diana Drive Glenfield Auckland New Zealand Tel 64 9 443 8072 Fax 64 9 443 8073 Email info nz ampac net HEAD OFFICE ...

Reviews: