background image

VT15/OM Rev-A 

 

3

Power Requirements 

Input Voltage: 

+9 to +16 Vdc, Reverse Polarity Protected 

Current Draw: 

UHF/L/S-Band  200 mA, 350 mA, 600 mA, 800 mA (for 250 mW, 500 mW, 1 W, 2 W) 

(Maximum) 

C-Band 

275 mA, 450 mA, 700 mA, 900 mA (for 250 mW, 500 mW, 1 W, 2 W) 

On/Off Control: 

Open = Off, Ground = On 

 

Mechanical 

Material: 

CNC Machined T6061-T6 Nickel Plated Aluminum 

Dimensions: 

1.25” W x 3.50” L x 0.35” H 

Weight: 1.5 

oz. 

Maximum 

Connectors: 

RF Output: 

SMA Female 

 

Video Input: 

SSMA Female  (Others Available) 

 DC 

Supply, 

On/Off: 

MDM-9P 

 

 

Audio/Mic Supply: 

MDM-9S 

(If Applicable) 

 

Environmental 

Temperature (Operating): 

-20°C to +50°C 

Humidity: 

Up to 95% @ Any Temperature Forming Frost or Condensation 

 

Summary of Contents for VT15 Series

Page 1: ...Rev A Operation Manual VT15 Series UHF L S C Band Video Audio Transmitters Designed and Manufactured By 2465 Old Hwy 40W Ste A Verdi NV 89439 Distributed By 107 Woodbine Down Blvd Units 7 8 Toronto ON...

Page 2: ...uctions 7 4 1 Use and Function of Connectors 7 4 2 Use and Function of Switches 8 4 2 1 Frequency Selection Switches 8 4 2 2 Dual Power Switch 8 4 2 3 Video Inversion Switch 9 4 2 4 Audio On Off Switc...

Page 3: ...designed for harsh environments and feature robust packaging and connectors Compact package sizes provide versatility in unit placement and system applications AMP Transmitters require no tuning or a...

Page 4: ...quency Response Specify 10 Hz to 3 5 MHz Monochrome 4 5 MHz NTSC or 5 5 MHz PAL 1 5 dB Pre Emphasis Specify 525 Line NTSC 625 Line PAL or None Modulation Sensitivity 4 MHz 1 Vpk pk Crossover Frequency...

Page 5: ...500 mW 1 W 2 W On Off Control Open Off Ground On Mechanical Material CNC Machined T6061 T6 Nickel Plated Aluminum Dimensions 1 25 W x 3 50 L x 0 35 H Weight 1 5 oz Maximum Connectors RF Output SMA Fe...

Page 6: ...VT15 OM Rev A 4 1 4 Mechanical Drawing and Connector Pin Outs...

Page 7: ...etc should be avoided Temperatures exceeding 75 C may cause permanent damage to the equipment When not used for extended periods of time external connections including power cable video cable and ante...

Page 8: ...Watts 1 Watt 2 Watts Antenna Minimum Minimum Minimum Minimum Gain EIRP Distance EIRP Distance EIRP Distance EIRP Distance dBi Watts Meters Watts Meters Watts Meters Watts Meters 0 0 25 0 20 0 50 0 20...

Page 9: ...he transmitter connect DC power supply to DC Power Cable red positive DC input black negative DC input ground Do not connect DC Power Cable to transmitter until all other connections are complete Conn...

Page 10: ...n the individual switches as shown in the applicable Frequency Selection Chart included with product shipment and available as a download on the applicable Video Product Page of our website www advmw...

Page 11: ...io subcarrier or two Line Only subcarriers An Audio On Off slide switch accessible through the chassis lid is provided only when two Line Only subcarriers are specified and enables disables both subca...

Page 12: ...an extended period all external cabling including the antenna should be removed and the unit should be stored in a container and placed in a clean dry environment 5 0 MAINTENANCE INSTRUCTIONS 5 1 Clea...

Page 13: ...paration for Reshipment If the transmitter and or any other purchased item s are to be shipped to another location or returned for repair or realignment use the original packaging or a sturdy box with...

Page 14: ...ping damage Limitation of Warranty The above warranty does not apply to defects of or resulting from the following 1 End items included as part of a system but not designed by AMP are subject only to...

Page 15: ...at 1300 MHz and is 1300 150 W m2 For VT50 UHF transmitters the operating frequency range is 340 400 MHz resulting in a MPE of 2 27 W m2 the lowest MPE in the 340 400 MHz range occurs at 340 MHz and i...

Reviews: