background image

AQS-EST1-F

How to Set Your Transmitter Configuration

Frequency Band

“C

onfig S

elec

t” P

reset

Preset

U1

L1

L2

S1

S2

S3

C1

C2

C3

1

340 MHz

1435 MHz

1700 MHz

2200 MHz

2400 MHz

2200 MHz

4400 MHz

4900 MHz

4400 MHz

2

344 MHz

1442 MHz

1711 MHz

2214 MHz

2407 MHz

2221 MHz

4436 MHz

4907 MHz

4443 MHz

3

349 MHz

1449 MHz

1721 MHz

2228 MHz

2414 MHz

2243 MHz

4471 MHz

4914 MHz

4486 MHz

4

353 MHz

1456 MHz

1732 MHz

2243 MHz

2421 MHz

2264 MHz

4507 MHz

4921 MHz

4528 MHz

5

357 MHz

1464 MHz

1743 MHz

2257 MHz

2428 MHz

2285 MHz

4543 MHz

4928 MHz

4571 MHz

6

361 MHz

1471 MHz

1754 MHz

2271 MHz

2435 MHz

2307 MHz

4579 MHz

4935 MHz

4614 MHz

7

366 MHz

1478 MHz

1764 MHz

2285 MHz

2442 MHz

2328 MHz

4614 MHz

4942 MHz

4657 MHz

8

370 MHz

1485 MHz

1775 MHz

2300 MHz

2450 MHz

2350 MHz

4650 MHz

4950 MHz

4700 MHz

9

374 MHz

1492 MHz

1786 MHz

2314 MHz

2457 MHz

2371 MHz

4686 MHz

4957 MHz

4742 MHz

A

379 MHz

1499 MHz

1796 MHz

2328 MHz

2464 MHz

2392 MHz

4721 MHz

4964 MHz

4785 MHz

B

383 MHz

1506 MHz

1807 MHz

2342 MHz

2471 MHz

2414 MHz

4757 MHz

4971 MHz

4828 MHz

C

387 MHz

1514 MHz

1818 MHz

2356 MHz

2478 MHz

2435 MHz

4793 MHz

4978 MHz

4871 MHz

D

391 MHz

1521 MHz

1829 MHz

2371 MHz

2485 MHz

2456 MHz

4829 MHz

4985 MHz

4913 MHz

E

396 MHz

1528 MHz

1839 MHz

2385 MHz

2492 MHz

2478 MHz

4864 MHz

4992 MHz

4956 MHz

F

399.9 MHz

1535 MHz

1850 MHz

2399 MHz

2499 MHz

2499 MHz

4900 MHz

4999 MHz

4999 MHz

FREQUENCY MULTIPLIER

100MHz 10MHz 1MHz

Your Frequency

4

4

1 3

This digit is always

constant for a given band

and is not adjustable

Transmitter/Receiver

rotary switches

for frequency selection

MHz

Diagram A - For 1 MHz Step - L-Band, S-Band, and C-Band

FREQUENCY MULTIPLIER

10MHz 1MHz 0.1MHz

Your Frequency

7

3

2 .1

This digit is always

constant for a given band

and is not adjustable

Transmitter/Receiver

rotary switches

for frequency selection

MHz

Diagram B - For 100 KHz Step - UHF 

The EST1 Transmitter has three modes for configuring the unit: Local Mode, Preset Mode, and 

Remote Mode (see manual for details). Local Mode utilizes DIP switches for configuring equipped 

options and rotary switches for frequency selection as shown below:

Pre-set Mode, selected when the two 10-position (BCD, 0-9) switches are set to zero and the 16-position 

(binary, 0-F) is set to any position 1-F, allows local selection among 15 pre-set configurations. The EST1 

transmitter ships from the factory with the 15 pre-sets configured with all options “ON” and set to their 

max settings with the frequencies set per the table below. Pre-sets may be changed as outlined in the 

ICD (Interface Control Document) via the communications port. Pre-sets are reprogrammable using 

Remote Mode, selected when all three rotary switches are set to zero. “Remote Only”  EST1 transmitters 

have no rotary switches installed. See the product manual for more details.

Wiring Your EST1 Transmitter

(Audio Connections are Dependent on Configuration )

SSMA Female

Video Input

(Connect to Camera)

SMA Female

RF Output

(Connect to Antenna)

MDM-9P 

Power & Programming

1:

2:

3:

4:

5:

6:

7:

8:

9:

+11 to 16 VDC Input

Ground

Ground

Ground

12 VDC Out

NC/TX Comm-

TX Comm+

RX Comm+

NC/RX Comm-

MDM-9S

Audio Input

1:

2:

3:

4:

5:

6:

7:

8:

9:

Audio 1 Mic

Audio 1 Line

Ground

Audio 2 Mic

Audio 2 Line

Ground

NC

NC

Ground

1

5

6

9

1

5

6

9

NC = No Connection

Reviews: