background image

AMP

®

 Estate Size Path & Area Lights 

3602 Series 

INSTALLATION & MAINTENANCE GUIDE

w w w. a m p l i g h t i n g . c o m

–2–

Important Safety Instructions: Read Before Installation

!

This luminaire is intended for installation in accordance with local codes 

and the National Electric Code (NEC). Failure to adhere to these codes and 

instructions may result in serious injury, property damage and void the 

warranty.

These instructions do not intend to cover all variations in installation, 

operation maintenance or mounting situations.

1.  Make sure the power is turned OFF before installing or servicing this 

luminaire.

2.  WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M) 

or more from pool, spa or fountain.

3.  This luminaire is intended to be used only with a power supply 

(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.

4.  Wiring connections must be made with UL listed wire connectors that are 

suitable for outdoor use.

5.  Position the low voltage wire and wire connector so that it is located 

within 6 inches (15.2 cm) from a building structure, a luminaire or 

fitting.

6.  The main low voltage cable is intended for shallow burial - less than 6 

inches (152 mm).

7.  If additional lengths of low voltage cable are required, please contact 

www.amplighting.com or call 1-813-978-3900.

Important Safety Instructions

!

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS

Lighted lamp is HOT!

WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.

1.  Turn off/unplug and allow to cool before replacing lamp.
2.  Lamp gets HOT quickly! Contact only switch/plug when turning on.
3.  Do not touch the hot lens, guard or enclosure.
4.  Keep lamp away from materials that may burn.
5.  Do not touch lamp at any time. Use a soft cloth. Oil from skin may 

damage lamp.

6.  Do not operate the luminaire fitting with a missing or damaged shield.

SAVE THESE INSTRUCTIONS

Summary of Contents for 3602 Series

Page 1: ...INSTALLATION MAINTENANCE GUIDE Help Hotline 1 813 978 3900 Mon Fri 9am 6pm EST www amplighting com AMP Line Voltage Landscape Lighting AMP Estate Size Path Area Lights 3602 Series ...

Page 2: ...ts 4 Wiring connections must be made with UL listed wire connectors that are suitable for outdoor use 5 Position the low voltage wire and wire connector so that it is located within 6 inches 15 2 cm from a building structure a luminaire or fitting 6 The main low voltage cable is intended for shallow burial less than 6 inches 152 mm 7 If additional lengths of low voltage cable are required please c...

Page 3: ...customersupport amplighting com 813 978 3900 Product Dimensions 3 Package Contents A 1 Fixture Body 10 25 6 3 Estate Size Hat featured on Estate Size Line Voltage Stem 36 ...

Page 4: ...02 Series Remove Stem Top Install Lamp Loosen the stem top and remove it from the top end of the stem Stem Stem Top Insert the lamp with the correct wattage and type marked on the fixture label and push firmly into place CAUTION Do not exceed maximum wattage marked on luminaire label Socket Lamp ...

Page 5: ... and Conduit Thread the stem top onto the stem and hand tighten until snug Stem Top Stem Dig a hole in the ground for the conduit runs and the stake Install the conduit Slide the stabilizer grid onto the stake and secure with the screws Place the stake over the conduit runs then backfill against the mounting stake Stake Stabilizer Grid Conduit Ground Level ...

Page 6: ... AMP Estate Size Path Area Lights 3602 Series Remove Cap from Stake Remove the cap from the stake by loosening the set screws Set Screw Cap Stake 6 Install Cap to Junction Box Thread the cap onto the Junction Box Cap Junction Box Junction Box is not provided ...

Page 7: ...ox onto the bottom of the fixture and hand tighten until snug Fixture Junction Box Supply Wires Screw Cover Junction Box is not provided 8 Install Junction Box to Stake Pass the main supply cable into the junction box Place the cap back onto the stake and secure with the previously removed screws Tighten until snug with a screwdriver Main Supply Cable Junction Box Cap Screw Stake Conduit Junction ...

Page 8: ...n supply cable leads Then connect the ground wires to the ground screw in the junction box After wiring carefully tuck the slack wires into the junction box Attach the cover back onto the junction box and secure with the previously removed screws Bury conduits and junction box Main Supply Cable Wire Connectors Junction Box Screw Cover Fixture Supply Wires Ground Screw Junction Box is not provided ...

Page 9: ... Top Finial Hat of your choice Remove the finial hat and stem top to expose the lamp and replace it with the correct wattage and type marked on the fixture label Then reinstall the stem top hat and finial IMPORTANT Lamps must be protected from moisture and dust at all times Always reinstall the stem top and hat when removed customersupport amplighting com 813 978 3900 9 ...

Page 10: ... 10 www amplighting com INSTALLATION MAINTENANCE GUIDE AMP Estate Size Path Area Lights 3602 Series ...

Page 11: ... 11 customersupport amplighting com 813 978 3900 ...

Page 12: ...tions and product details subject to change without notice Copyright 2019 AMP Lighting Lutz FL USA 33549 All rights reserved customersupport amplighting com 813 978 3900 Help Hotline 1 813 978 3900 Mon Fri 9am 6pm EST www amplighting com ...

Reviews: