AMOT CHALWYN MPX-Series Maintenance Manual Download Page 2

DESCRIPTION

A range of 3”, 5” and 8” bore slim butterfly air intake shut down valves with air pressure actuated shut down 

combined with manual reset and the optional addition of manual shut down. Suitable for both hazardous 

and non-hazardous area applications. MPX valves are available in basic flange mounted form or fitted with 

hose adaptors. Valve body and disc are manufactured in corrosion resistant hard anodised aluminium with 

PTFE coating. The valve spindle and mechanism is made from stainless steel.

1/8" NPT for

connecting air

pressure supply

Optional Hose

Adaptors

C1

C2 (min)

C2 (max)

Reset Lever

B

A

Valve Types MPX-300, MPX-500 and MPX-800  

(Air Pressure Shut Down, Manual Reset)

Main Dimensions (mm)

Valve Type

 

MPX-300

MPX-301

MPX-302

MPX-303

MPX-310

MPX-500

MPX-501

MPX-502

MPX-503

MPX-510

MPX-800

MPX-801

MPX-802

MPX-803

Nominal Bore 

Diameter

 

76 (3”)

127 (5”)

203 (8”)

minimum & maximum

A

 

190.0

207.0

190.0

223.0

246.0

263.0

246.0

279.0

346.5

362.0

346.5

377.5

B

 

111.5

167.0

257.0

C1

 

37.5

45.5

56.0

C2

82.5 to 112.5

102.0 to 157.5

136.5 to 185.5

Notes:

Maximum temperature of the engine intake air at the MPX valve not to exceed 150°C.  (See also 

‘Installation” - page 5).
For alternative types of air pressure actuated Chalwyn valves see brochure CE218.

2

MPX  DIESEL ENGINE SHUTDOWN VALVES 

CE236 (9)

T: +44 (0)1284 715739  

[email protected]

Valve models MPX-310 and MPX-510 have a 
built-in microswitch. This enables an indica-
tion of the valve open/close status. The micro-
switch connections are made as follows: 
Brown = supply - common
Blue = makes circuit when valve is closed
Black = make circuit when valve is open

Maximum rating of microswitch at 12 or  
24 V = 2 amp

Summary of Contents for CHALWYN MPX-Series

Page 1: ...MPX 303 MPX 310 MPX 500 MPX 501 MPX 502 MPX 503 MPX 510 MPX 800 MPX 801 MPX 802 MPX 803 MPX Series Diesel Engine Shut Down Valves Manual Reset Air Pressure and Manual Closure Options Selection Applica...

Page 2: ...PX 301 MPX 302 MPX 303 MPX 310 MPX 500 MPX 501 MPX 502 MPX 503 MPX 510 MPX 800 MPX 801 MPX 802 MPX 803 Nominal Bore Diameter 76 3 127 5 203 8 minimum maximum A 190 0 207 0 190 0 223 0 246 0 263 0 246...

Page 3: ...C2 min C2 max B A 1 8 NPT for connecting air pressure supply Optional Hose Adaptors Reset Lever Stop Button C1 C2 min C2 max B A Valve Types MPX 301 MPX 501 and MPX 801 Air Pressure and Integral Stop...

Page 4: ...511 121 4 3 4 HAX 512 124 4 7 8 HAX 513 127 5 HAX 518 140 5 1 2 HAX 523 152 6 Select the required length of the manual shut down cable from the table Alternative lengths may be available on request Al...

Page 5: ...pipework should be used and any gaps kept as short as possible taking into account any relative movement and closed by reinforced hose The possibility of a hose collapse on clo sure of the shut down...

Page 6: ...n handle and tighten Refit handle locknut and handle Tighten locknut 10 Connect shut down air supply using the 1 4NPT tapping on valve Means must be provided to release any trapped air pressure at the...

Page 7: ...d support bracket fasteners are securely tightened Check that any intake system hoses between the MPX valve and engine are free from damage and suitable for further service Run engine preferably at or...

Page 8: ...co uk www chalwyn com A division of Roper Industries Limited UK Western Way Bury St Edmunds Suffolk IP33 3SZ Tel 44 0 1284 715739 Fax 44 0 1284 715747 USA 8824 Fallbrook Drive Houston TX 77064 Tel 1 2...

Reviews: