![AMOT 4103D Manual Download Page 6](http://html1.mh-extra.com/html/amot/4103d/4103d_manual_2933824006.webp)
Temp. Valve for Static Bearings - Models 4103D/M
Datasheet_4103_Temperature_Valve_FEB18_Rev2
Page 6
Table 1 - 4103D
Code
Installed depth and fuse rod
length
Minimum
Maximum
mm
inches
mm
inches
03
27.0
1
1⁄16
”
39.7
1
9⁄16
”
04
47.6
1 ⅞”
57.2
2 ¼”
05
60.3
2 ⅜”
69.9
2 ¾”
06
73.0
2 ⅞”
82.6
3 ¼”
07
85.7
3 ⅜”
95.3
3 ¾”
08
98.4
3 ⅞”
108.0
4 ¼”
09
111.1
4 ⅜”
120.7
4 ¾”
10
123.8
4 ⅞”
133.4
5 ¼”
11
136.5
5 ⅜”
146.1
5 ¾”
12
149.2
5 ⅞”
158.8
6 ¼”
13
161.9
6 ⅜”
171.5
6 ¾”
14
174.6
6 ⅞”
184.2
7 ¼”
15
187.3
7 ⅜”
196.9
7 ¾”
16
200.0
7 ⅞”
209.6
8 ¼”
17
212.7
8 ⅜”
222.3
8 ¾”
18
225.4
8 ⅞”
235.0
9 ¼”
19
238.1
9 ⅜”
247.7
9 ¾”
20
250.8
9 ⅞”
260.4
10 ¼”
Table 2 - 4103M
Code
Installed depth and fuse rod
length
Minimum
Maximum
mm
inches
mm
inches
00
19.1
¾”
27.0
1
1⁄16
”
01
41.3
1 ⅝”
49.2
1
15⁄16
”
02
47.6
1 ⅞”
55.6
2
3⁄16
”
03
54.0
2 ⅛”
61.9
2
7⁄16
”
04
60.3
2 ⅜”
68.3
2
11⁄16
”
05
66.7
2 ⅝”
74.6
2
15⁄16
”
06
73.0
2 ⅞”
81.0
3
3⁄16
”
07
79.4
3 ⅛”
87.3
3
7⁄16
”
08
85.7
3 ⅜”
93.7
3
11⁄16
”
09
92.1
3 ⅝”
100.0
3
15⁄16
”
10
98.4
3 ⅞”
106.4
4
3⁄16
”
11
104.8
4 ⅛”
112.7
4
7⁄16
”
12
111.1
4 ⅜”
119.1
4
11⁄16
”
13
117.5
4 ⅝”
125.4
4
15⁄16
”
14
123.8
4 ⅞”
131.8
5
3⁄16
”
Valve Characteristics
Installed depth and fuse rod length