User Guide - ATU 

 

 

6 von 8

 

Technical Data are subject to change without 

notice

 

User Guide ATU v.5.0 Test 

kit.docx-5.0

 

 

 

 

6  Measuring of signal accuracy (only ATU-2) 

Check  the  geometrical  mounting  conditions  (use  Mounting  Instructions 

http://www.amo-

gmbh.com/

 

Before  measuring  of  signal  accuracy  ensure  that  you  get  no  error  for  total  measuring  distance 
using Position measurement function. 

If  the  ATU  Box  was  connected  successfully,  you  can  measure  signal  accuracy  by  activating  of 
“Signal accuracy” window. 

 

 
The  signal  deviations  can  be  evaluated  by  moving  the  measuring  head  along  the  scale  (or 
measuring flange) with a constant speed. 
 

Setting the speed precision and number of periods 

Here  you  have  an  opportunity  to  set  measurement  speed  precision  (between  1  and  30%)  and 
minimal periods quantity for measurement (between 50 and 2100). The precision of evaluation is 
higher  for uniform speed  (e.g. 

Speed  precision

  below  10%) and  longer measuring  stroke  (e.g. 

Minimal  periods

  higher  than  70).  Try  to  optimize  these  two  values  in  order  to  get  higer  signal 

accuracy value. 
Getting a higher speed accuracy score means a higher mounting accuracy according to Mounting 
Instructions. 
 

To  start  measurement  process  click  “Start”  button.  If  measurement  goes  correct,  you  will  see 
progress field filling.  

After getting valid measurement data, you will see signal accuracy and the speed deviation in the 
same-named field. 

To abort measurement process click “Stop” button.  

Before closing programm, please break connection with ATU Box by clicking “Device connected” 
button. 

 

 
 

Summary of Contents for ATU

Page 1: ...v 5 0 Test kit docx 5 0 AMO GmbH ATU Test kit Contents 1 Generalities 2 2 Software Installation 3 3 Hardware 4 4 Software Manual 4 5 Position measurement ATU 1 and ATU 2 5 6 Measuring of signal accura...

Page 2: ...ATU 1 connection scheme Pic 2 ATU 2 connection scheme Minimal PC requirements Processor 1GHz RAM 512 MB Operating system Windows XP or higher Hardware ATU Box ATU 1 or ATU 2 USB cable ATU to PC Conne...

Page 3: ...to change without notice User Guide ATU v 5 0 Test kit docx 5 0 ATU 1 Test Kit ATU 2 Test Kit 2 Software Installation Download software from official site of AMO GmbH http www amo gmbh com Launch the...

Page 4: ...ized and installed the ATU Box Connect ATU Box with measuring head using connection scheme Page 2 4 Software Manual Start the Software with desktop icon or file AMO_ATU exe in installed folder Select...

Page 5: ...sages Please follow the instructions and try again To stop measurement process click Stop button If you need to set 0 position click Set current position as 0 button The button will change name to Res...

Page 6: ...f periods Here you have an opportunity to set measurement speed precision between 1 and 30 and minimal periods quantity for measurement between 50 and 2100 The precision of evaluation is higher for un...

Page 7: ...www amo gmbh com If the ATU Box was connected successfully you can start getting functional reserve value with click at Start button The Functional Reserve value is updated during the movement After...

Page 8: ...BiSS C Encoder registers Get Register button reads all the registers form the current slave By double clicking on a value the user is able to type a new value for the register All values are in hexade...

Reviews: