Next
REAR PANEL
Sensor
DC supply : 12 Volts 400 mA
1
+
-
V+
SENSOR
OPTO MOS 2
8
OPTO MOS 1
LAN
GPO1
GPO2
DC supply : 12 Volts 400 mA
THRU
GPO1
GPO2
Wiring with an AFF04 display
Connect a EIA/TIA 568B between AFFseries RJ45 socket
(GPO1/GPO2) and AFF04 RJ45 socket (GPO1/GPO2)
Connect the CAP65 sensor to AFFseries display.
Connect the AFFseries display to the provided supply .
PS 12V
Sensor
AFFseries-2 (ex AFF25)
AFF04
V+
DC SUPPLY
1
2
3
4
DC supply : 12 Volts 400 mA
1
+
-
V+
SENSOR
OPTO MOS 2
8
OPTO MOS 1
LAN
GPO1
GPO2
V+
DC SUPPLY
1
2
3
4
DC supply : 12 Volts 400 mA
1
+
-
V+
SENSOR
OPTO MOS 2
8
OPTO MOS 1
LAN
GPO1
GPO2
Wiring with the SNA50-3 or SA70-3 limiter:
You can connect two displays directly on the SNA. One display power supply box is needed.
Note : If you want to connect more than two displays or connectable accessories, then please contact
us.
K
L
J
Gnd
V+
4
1
Caution: Do not connect any
computer to this jack, excess risk
of damage to your network
adapter.
ILS
+
+
+
-
-
-
1
5
9
230V 50/60Hz 14W T
250mA
Made in France (Fr)
0V
+12V
AFF
POWER IN
1
Max 230V/1A
2
&
RJV
VCA
Fire
Alarm
Pre
Alarm
window
Piezo
Electret
L
R
L
R
INPUT
OUTPUT
CAP
GPO1/GPO2
AFF DISPLAYS
PUSH
PUSH
AFFseries rear panel
AFF04 rear panel
AFF power
supply
AFF power
supply
Connect a EIA/TIA 568B between AFF RJ45 socket (GPO1/GPO2), and
socket
K
on SNA50-3 or SNA70-3.
Connect a second EIA/TIA 568B between the second AFF RJ45 socket
(GPO1/GPO2), and socket
J
on SNA50-3 or SNA70-3.
This wiring handles power supply and measuring audio.
AFFseries rear panel
AFF rear panel
1
1
+
+
-
-
V+
V+
SENSOR
SENSOR
OPTO MOS 2
OPTO MOS 1
8
8
J
K
31
AMIX
AFFseries-2