![AMIX AFF12 pack 01 User Manual Download Page 13](http://html.mh-extra.com/html/amix/aff12-pack-01/aff12-pack-01_user-manual_2933471013.webp)
AMIX
AFF12
13
Next
Wiring two displays AFF12 with SPL25
Sensor
CAP65
SPL25
AFF12
AFF12
AFF12 power supply
SPL25 power supply
Capteur
CAP65
DC supply : 12 Volts 400 mA
1
+
-
V+
SENSOR
OPTO MOS 2
8
OPTO MOS 1
LAN
GPO1
GPO2
SPL25 rear panel
P. SUPPLY OUT
P. SUPPLY IN
TO FLASH RED
CONNECT 2 AND 3
DC SUPPLY 12V - 650 mA max
Made in France (Fr)
THRU
IN
GPO1
GPO2
P. SUPPLY OUT
P. SUPPLY IN
TO FLASH RED
CONNECT 2 AND 3
DC SUPPLY 12V - 650 mA max
Made in France (Fr)
THRU
IN
GPO1
GPO2
INSTALLATION GUIDE
AFF12 rear panel
AFF12 rear panel
SPL25
power supply
AFF12
power supply
Connect the SPL25 and the first AFF12 display
with a RJ45 cable (straight wiring). Maximum 5
meters.
Connect the CAP65 sensor to SPL25.
To power the unit, connect the SPL25 to the
supplied power supply.
Then connect the first AFF12 display to the second
AFF12 with another RJ45 cable (straight wiring).
Maximum 5 meters.
To power the second AFF12, connect it to the
supplied display power supply.
For further information, refer to the SPL25
manual.