WRTB1
XX
19/42
wrtb1xx_g_en_105
4.1. Other tests
Router has been assessed and approved for use in railway applications
according to standards:
Tested in accordance
with standard
Type of test
Result
EN 50155:2007
Railway applications
– Electronic
equipment used on rolling stock
Complies
EN 50121-3-2:2006
Railway applications
– Electromagnetic
compatibility (EMC)
– Part 3-2 Rolling
stock
– equipment
Complies
EN 61373:2010
Railway applications
– Rolling stock
equipment
– Shock and vibration tests.
Category 1,
Class B
EN 61000-4-29:2000
Electromagnetic compatibility (EMC)
– Part
4-29: Testing and measurement
techniques
– Voltage dips, short
interruptions and voltage variations
immunity tests
S1, C1
EN 60068-2-1:2007
Environmental testing
– Part 2-1: Tests –
Test A: Cold
Complies
EN 60068-2-2:2007
Environmental testing
– Part 2-2: Tests –
Test B: Dry heat
Complies
EN 45545-2:2013
Railway applications
– Fire protection on
railway vehicles
HL3