RRU-WTB/AN01
9/28
rru-wtban01_g_en_100
Mechanical design
Compact aluminium tube, anodized black
Front and rear panel made of aluminium
alloy with anti-corrosion coating
1
)
Mounting
Into 19“ subrack
Ingress protection rate
IP30
2
)
Weight
– netto
– brutto
1.55 kg ±5 %
1.
85 kg ±5 %
Dimensions in standard units (w × h)
28 HP × 3 U
3
)
Dimensions (w × h × d)
(142 × 129 × 204) mm
4
)
1
) Front panel is made from aluminium alloy without detail specifying of
additives composition. Surface is naturally anodized.
2
) After all cable connectors are connected.
3
) 1 HP (horizontal pitch) = 0.2 inch (5.08 mm),
1U (rack unit) = 1.75 inch (44.45 mm).
4
) Depth, including inserted power supply connector.
Unit overall mass of plastics
213 g
Included mass of self-extinguishing
plastics
213 g
Device does not contain
PUR, PVC, Asbestos
Device conforms
2011/65/EU (ROHS)
1907/2006EU (REACH)
Operating temperature range
-
40 °C to 70 °C
Operating temperature range
-
40 °C to 70 °C
Maximum ambient humidity
< 95 % non-condensing
Reliability (MTBF) min.
180 000, at 40
°C ambient temperature,
methodology acc. to MIL HDBK217F2 Part
Stress
1
)
1
) Contact manufacturer for updated values.
None
Analyser is supplied with loader, which enables software downloading by application
ADS Manager via Ethernet line.
WTB analyser is intended to operate up to 1 400 m above the sea level.
WTB analyser is designed to meet the Temperature Class TX.
According to EN 61373:2010 standard, the equipment is classified in terms of
vibrations into Category 1, Class A (mounting to vehicle body).
Permissible supplying voltage drop-outs duration: max 10 ms (Class S2 according to
Chapter 3.1.1.2 of EN 50155:2007.
For supply voltage switching
– conditions of C1 and C2 Class are permissible.
Mechanics
Dangerous
materials
Temperatures
Others
Components
with reduced
lifetime
Software
Claims of EN
50155:2007