background image

 

aipqb1215wa6101_g_en_101 

AIPQB1215WA61/01 

 

TFT panel for rolling stock 

Operation manual 

Version 1.01 

 

Summary of Contents for AIPQB1215WA61/01

Page 1: ...aipqb1215wa6101_g_en_101 AIPQB1215WA61 01 TFT panel for rolling stock Operation manual Version 1 01...

Page 2: ...le text all pages must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document mu...

Page 3: ...used 16 4 1 2 SB input is not used 17 5 Digital inputs outputs 18 6 Communication lines and peripherals 20 6 1 RS422 20 6 2 Audio 21 6 3 Ethernet 22 6 4 USB 23 6 5 Indication LED 24 7 Mounting 25 7 1...

Page 4: ...ame aipqb1215wa6101_g_en_101 pdf Author Ond ej Rott Revision Date Changes 100 7 4 2015 New document 101 1 9 2015 Changes in 2 Technical parameters 2 4 Recommended drawing symbol 4 Power supply 5 Digit...

Page 5: ...rnet 10 100 Mbps interface with M12 connector Indication LED Power supply 24 V DC Mounting on vehicle body Design according to EN 50155 2007 TFT panel AIPQB1215WA81 01 operates without limitation in t...

Page 6: ...ed cabling Shielded USB cable Quantity 1 Operation indication No Galvanic separation No Insulation strength 500 V AC 1 minute Terminating resistor 120 Maximum transmission rate 115 kbps Recommended ca...

Page 7: ...ording to IEC61375 3 4 Recommended cabling STP CAT6 Maximum segment length 100 m Insulation must not be used for dangerous voltage separation Nominal power supply voltage 24 V DC Power supply voltage...

Page 8: ...nded to operate up to 1 400 m above the sea level Equipment design meets the requirements of temperature class T3 with temperature lower range extension and limitation of full operating functionality...

Page 9: ...AIPQB1215WA61 01 9 36 aipqb1215wa6101_g_en_101 2 1 Dimensions 553 8 61 7 157 8 360 0 335 1 Fig 1 AIPQB1215WA61 01 dimensions 2 2 Connector location Fig 2 Location of AIPQB1215WA61 01 connectors...

Page 10: ...ed to be used with 4 M8 screws 35 0 4 x O 9 350 0 Fig 3 Location and dimensions of AIPQB1215WA61 01 mounting holes 2 4 Recommended drawing symbol Following drawing symbol is recommended for AIPQB1215W...

Page 11: ...nit type designation S N xxxxxxx Serial number POWER 24 V DC 1 25 A Power supply voltage WEIGHT 9 50 kg Weight TEST OK xx Routine testing result HiPot HiPot OK HiPot test result DATE dd mm yyyy Produc...

Page 12: ...AIPQB1215WA61 01 aipqb1215wa6101_g_en_101 12 36 Fig 6 Location of type label illustrative picture...

Page 13: ...art 4 3 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test 1000 MHz to 2100 MHz 10 V m EN 61000 4 3 2006 Electromagnetic compatibility EMC Part 4 3 Testing...

Page 14: ...06 Railway applications Electromagnetic compatibility Part 3 2 Rolling stock Apparatus Complies EN 61373 2010 Railway applications Rolling stock equipment Shock and vibration tests Complies EN 60068 2...

Page 15: ...ND Power supply GND 5 Vcc Power supply 24 V DC 6 PE Monitor chassis The PE terminal is internally connected with TFT panel cover and with metal caps of all connectors When installing it is recommended...

Page 16: ...n Only after completion of operating system run and unit s shut down the supply voltage can be disconnected from terminal Vcc or voltage can be left connected to Vcc terminal permanently Voltage wavef...

Page 17: ...realized either by coincident connecting of power supply voltage to Vcc and SB terminals or by connecting the voltage first to Vcc terminal and then to SB or vice versa Nevertheless when starting up a...

Page 18: ...input and output simultaneously PWR X1 ETH X3 AUDIO RS422 X4 1 LNK SYS ACT HDD USB X2 DIO2 1 DIO1 2 SB 3 GND 4 Vcc 5 PE 6 Fig 10 Location of AIPQB1215WA61 01 power supply connector Number Meaning 1 Co...

Page 19: ...ND Setting the output to log 1 will connect power supply voltage to DIOx terminal Setting log 0 will disconnect power supply voltage from DIOx terminal Then it can be used as a digital input Outputs a...

Page 20: ...n both DIP switch contacts are ON line termination is activated Connector type D sub DE 9 socket Connector PIN Signal Type of signal on AIPQB1215WA81 01 X4 1 AUX R Audio output R 2 Rx RS422 input posi...

Page 21: ...t Connector PIN Signal Type of signal on AIPQB1215WA81 01 X4 1 AUX R Audio output R 2 Rx RS422 input positive polarity 3 Rx RS422 input negative polarity 4 Tx RS422 output positive polarity 5 AGND Aud...

Page 22: ...ng 1 Connector X3 Ethernet Activity of Ethernet line is indicated by LNK and ACT LED indicators which are located on the front mask of TFT panel The LNK LED indicates connecting of network cable with...

Page 23: ...61 01 has 2 USB ports built in with A type connectors according to USB 2 0 standard Connectors are located on the rear side of TFT panel mechanics PWR X1 ETH X3 AUDIO RS422 X4 1 LNK SYS ACT HDD USB X2...

Page 24: ...its internal temperature is in the range for full functionality Light Device internal temperature is out of range for full functionality Blinking HDD green Not used LNK green Connecting to 100 Mbps E...

Page 25: ...panel mounting consist of following steps Preparing the workplace Casing removal Unmounting console Mounting console on the wall Connection of cabling Mounting display Mounting cover 7 1 1 Preparing...

Page 26: ...2 x M4 2 x M4 Fig 19 Location of M4 screws on the unit s cover Internal part of TFT panel is connected to the cover with yellow green PE protective conductor Disconnect faston connector on the yellow...

Page 27: ...part 7 1 3 Unmounting console Loosen 4 M6 screws as shown on figure below Do not remove M6 screws completely just loosen them Remove supporting console by pulling in the direction of arrows 2 x M6 2 x...

Page 28: ...ribed in chapter 2 3 7 1 5 Connection of cabling Connect any required cabling to the internal part of TFT display containing electronics and display Location of connectors is shown in chapter 2 2 Cabl...

Page 29: ...display to the console 4 x M6 4 x M6 Fig 26 Location of 4 M6 screws 7 1 7 Mounting cover Connect the free end of the yellow green protective conductor to the faston connector on the unit s cover Put t...

Page 30: ...AIPQB1215WA61 01 aipqb1215wa6101_g_en_101 30 36 Fig 27 Location of the faston on the unit s cover Fig 28 Putting the outer cover on the TFT panel...

Page 31: ...Mounting claims PE terminal of power supply connector must be connected with local installation earthing terminal Power supply conductors cross section must be at least 0 75 mm2 Ethernet connection c...

Page 32: ...unterpart WAGO 769 104 021 000 1 Routine testing protocol 1 Insulation testing protocol 1 Certificate of product quality and completeness 1 8 2 Connectors M12M04D MC A M12 connector counterpart 4 pins...

Page 33: ...ted in chapter Technical parameters Sticker on the box contains following information Item Description TYPE AIPQB1215WA61 01 NETTO 9 50 kg BRUTTO 11 00 kg QTY 1 pc S N Serial number Logo AMiT QR code...

Page 34: ...be stored in any position If boxes are stockpiled weight acting on the top side of the box must not exceed 15 kg All load must be evenly spread over the entire upper side of the box Device without pa...

Page 35: ...nance With exception of cleaning the device requires no periodic control nor maintenance Depending on equipment usage the dust is to be removed occasionally from equipment The display surface can be c...

Page 36: ...disposal The disposal of electronic equipment is subject to the regulations on handling electrical waste The equipment must not be disposed of in common public waste It must be delivered to places spe...

Reviews: