background image

Please, read and follow the installation and operating instructions carefully, to ensure the long life and reliable 

operation of this appliance.

Kospel S.A. may make minor changes if necessary, in the appliance, that will not be shown in the operating 

instruction, so long as the main features of the heater remain the same.

KOSPEL S.A.

     75-136 KOSZALIN  UL. OLCHOWA 1

epo_d1v8_1

Summary of Contents for EPO.D1-4

Page 1: ......

Page 2: ...ure the long life and reliable operation of this appliance Kospel S A may make minor changes if necessary in the appliance that will not be shown in the operating instruction so long as the main features of the heater remain the same KOSPEL S A 75 136 KOSZALIN UL OLCHOWA 1 epo_d1v8_1 ...

Page 3: ...the water in accordance with the following technical specifications The heater features covered insulated heating coils that assure maximum safety materials resistant to corrosion and chemically inactive towards water copper brass and stainless steel Description Technical data if the appliance is supplied from 400V 2N EPO D1 Water Heater 4 5 6 Rated Power kW 4 5 6 Power Consumption kW 2 2 2 5 2 5 ...

Page 4: ...connected to a cold water supply pipe only a non return valve cannot be in stalled on the supply pipe inlet and outlet pipes should not be made of plastic the heater works in conjunction with taps and mixers without a thermostat Assembly 1 Bring the domestic water and the electricity supply observing normal safety standards to the point where the heater is to be mounted Diagram No 2 shows how to c...

Page 5: ...ires at the back base to live parts Diagram 4 Electric connection a electric connection to the 1 phase installation b electric connection to the 3 phase installa tion F circuit breaker M1 a bridge connecting clamps U and V L live wire N neutral wire PE earth wire L1 live wire 1 L2 live wire 2 If the appliance is supplied from two phases the bridge M1 con necting terminal clamps U and V installed b...

Page 6: ...p at maximum flow insert the spanner 15 into the regulation valve 9 set optimum flow check if the temperature is comfortable for you using the spanner take the spanner 15 out of the regulation valve 9 close water flow using the tap The reccommended maintenance needs to be repeated each time after a decay of water If the water installation is not vented the appliance may be damaged 1 Cut off electr...

Page 7: ... the filter 12 in the former position 6 Connect cold water supply pipe ZW with the inlet pipe 7 7 Open cold water pipe on water supply check connections for le aks 8 Vent the installation and the heater according to START UP instruc tions 7 Picture 7 Filter cleaning 7 water inlet cold water 12 filter ZW cold water connection U gasket We recommend always cleaning the filter after any repairs to the...

Page 8: ...ase 6 orifice 7 water inlet cold water 8 water outlet hot water 9 flow regulating valve 11 terminals 14 entry access for electric wire This heater has an overheating protection its over temperature cut out goes off shuts off power supply when the temperature in the heating box 1 goes over 95o C Once the cut out gets off further operation is not possible 8 Construction ...

Page 9: ...above given please contact the nearest service branch 9 Faults If you notice any of the following signs of improper work follow the instructions below no or insufficient heating a failure of the power supplies for instance a fuse rate of flow through the heater is too small the filter might be blocked with impurities or the flow regulating valve is set improperly no bridge M1 picture 4a 4b in case...

Page 10: ...s This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and know ledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance ...

Page 11: ......

Page 12: ......

Reviews: