Electrical Connections 

AMICO Circulator doesn't need an external motor protection.  
Check if voltage and frequency are consistent with values in the pump 
plate. 
The circulator is working when the control-panel-light turns on. 
If the power cord is damaged, it must be replaced. 
Protection fuse: 1A. 

 

 

Electrical Connection

 

Electric Cable  
Max diameter 10mm 
Min diameter 5mm

 

Insert  the  cables 
in  the  correct  or-
der 

Cable is 

0,75mm

 

WARNING! 

AMICO  Circulator must be connected to the ground wire. 
The pump must be connected to an external power switch. 
The min. clearance between the electrodes should be 3mm. 

14 

The pump is equipped with the function S3, self purging function. After 
the start of this setting, the air in the pipes (cause of noise and malfunc-
tions) wears off after a few minutes. 
 

10. Relations between pump setting and performance 

Such reports shall be expressed in the diagram below. 

Expulsion of air 

It means running 

for 5 minutes 

Do not start the pump without pumping liquid. 
Do not start the pump before expelling the air in the pipes. 

Summary of Contents for AMICO 20-4-130

Page 1: ...www xpowerwaterpumps com www xpowerwaterpumps com AMICOCIRC Intelligent Frequency Conversation Circulation Pump Handbook ...

Page 2: ......

Page 3: ...ducts Amico circ20 4 130 220V 50 60Hz Amico circ25 4 130 220V 50 60Hz Amico circ25 4 180 220V 50 60Hz Amico circ32 4 180 220V 50 60Hz Amico circ20 5 130 220V 50 60Hz Amico circ25 5 130 220V 50 60Hz Amico circ25 5 180 220V 50 60Hz Amico circ32 5 180 220V 50 60Hz Amico circ20 6 130 220V 50 60Hz Amico circ25 6 130 220V 50 60Hz Amico circ25 6 180 220V 50 60Hz Amico circ32 6 180 220V 50 60Hz Fulfil the...

Page 4: ...e of long periods of inactivity make sure to close the inlet and outlet valves 12 If the supply cord or the plug are damaged please ask a qualified centre to replace them 13 If the temperature of the pump is greater than the value of name plate remove the power disconnect the pump through the valves on the pipeline and please contact your local dealer or service 14 If you are unable to find a solu...

Page 5: ...r cir culation Innovative and easy to install it is used in heating and air condi tioning systems The permanent magnet technology combined with the frequency con verter allowing the engine to run automatically according to the real needs 2 Main Features 1 Simple and compact structure 2 Different adaptive control modes 3 Combine control over two different compression pressure differ ences 4 Display...

Page 6: ...n Then set up the speed control switch to the S3 speed and check if AMICO starts normally The network and relative outlets must be fitted with an efficient earthing connection following the laws in force on the matter of elec trical systems Do not change the power ground plug without authorization Please affix a warning sign on the pump operating site Regularly check the pump insulation resistance...

Page 7: ...m Water column 110 C 0 108MPa 1 08 Bar 10 8m Water column Electromagnetic compatibility EMC standard EN 61000 6 1 e EN 61000 6 3 Sound pressure le vel SPL Less than 43 Decibel Ambient temperatu re From 0 C to 40 C Temperature class TF110 Surface temperature Less than 125 C Liquid temperature 2 C to 110 C 2 Installation of Amico Circulator The arrows on the pump housing indicate the direction of li...

Page 8: ...remove the four screws holding the pump head Figure 1 Turn the pump head to the desired position Figure 2 Replace the four hex screws Bolt and tighten crosswise Figure 3 WARNING The pump housing might be incandescent It can cause scalds and burns Before any intervention on the circula tor you have to drain the system and close the valves 5 2 3 Different positions of the Junction Box 16 Performance...

Page 9: ...ction of the required flow to work at constant pressure close to the minimum as reported in the graph CP2 Max constant pressure curve The CP2 mode allows the pump in function of the required flow to work at constant pressure close to the maximum as reported in the graph S1 I Speed I The pump maintains minimum speed III set by the operator in any working condition S2 II Speed II The pump maintains ...

Page 10: ...5mm WARNING AMICO Circulator must be connected to the ground wire The pump must be connected to an external power switch The min clearance between the electrodes should be 3mm 7 14 The pump is equipped with the function S3 self purging function After the start of this setting the air in the pipes cause of noise and malfunc tions wears off after a few minutes 10 Relations between pump setting and p...

Page 11: ...make sure that the system is filled with liq uid and that all the air is drained out The pressure should reach the mini mum required level 9 2 Switch the setting to Speed III S3 self purging function for a few minutes Then switch to AUTO mode or change setting 1 3 2 Manual by pass Valve Auto by pass Valve System installed with bypass valve 13 8 Operation Instructions 1 Operation Panel 1 1Operating...

Page 12: ... the fixed speeds S1 S2 S3 is running night mode does not work In the event of a power failure the night mode must be restarted If the heating system does not provide enough heat we recommend to disable the night mode To ensure NIGHT MODE peak performance The pump must be installed in the water supply pipe near the water heater If the pump will be installed in the return water pipeline auto night ...

Page 13: ...tional pressure curve it is indicated by PP1 and PP2 Constant pressure control Under this control mode the pressure dif ference keeps stable and it is irrelevant to flow at both ends of the pump Constant pressure curve is indicated by CP1 and CP2 In Q H there is a horizontal performance curve WARNING AmicoPump installed in heating system with boiler with tank cannot be set to AUTO RED Inlet pipe s...

Reviews: