![Amica PB*4VI510FTB SERIES Instruction Manual Download Page 18](http://html.mh-extra.com/html/amica/pb-4vi510ftb-series/pb-4vi510ftb-series_instruction-manual_2932497018.webp)
18
OPERATION
Automatic warming
• The selected burner must be set at “0” heating power.
• The heating power will switch to 9 the moment button (
4
) is pressed.
• Then, press “+” button (
2
) for the respective burner. “A” will light up in the display.
• Next, select the desired heating power with button (
4
).
“A” and the preset requested heating power indication for the burner blink in the re-
spective display in successive turns.
The burner will automatically switch to the preset heating power after the time of extra
power supply has elapsed. That power value will be indicated in the display.
Note. If the heating power selector
remains at “0” position for more
than 3 seconds after the quick
heating function is switched off
(i.e. heating power in unchanged),
the quick warming feature goes
off, too.
If the pot is removed from the bur-
ner and is placed on it again wi-
thin 10 minutes, the extra waring
will be executed completely.
Heating power
Automatic extra
warming duration
(minutes)
1
0,8
2
2,4
3
3,8
4
5,2
5
6,8
6
2,0
7
2,8
8
3,6
9
0,2
Limited time of operation
To increase its reliability the plate is pro-
vided with an operation time limiter for each
hotplate. The maximal times of operation
depend on the last selected heating power
level. A hotplate switches off automatically
if the heating power has not been changed
during the specified time (see the Table) and
the residual time indicator is lighted. You can
however switch on and use the respective
hotplates in accordance with the Operating
Manual.
Heating power
level
Maximal time of
operation in hours
1
6
2
6
3
5
4
5
5
4
6
1,5
7
1,5
8
1,5
9
0,13
Summary of Contents for PB*4VI510FTB SERIES
Page 1: ...IOAA 509 10 2010 1 PB 4VI510FTB GB INSTRUCTION MANUAL 2 ...
Page 26: ...26 ...
Page 27: ......
Page 28: ......