OPERATION AND MAINTENANCE

Maintenance

Regular maintenance and cleaning of the device 

will ensure faultless operation, and help extend the 

life of the unit. Attention should be paid to replacing 

grease and carbon filters according to instructions.

Aluminium grease filter

Cleaning

For normal hood operation, aluminium grease filter 

should be cleaned every month in the dishwasher 

or by hand using a mild detergent or liquid soap. 
To replace:

Dismantling of aluminium grease filter is shown on 

Figure 5.

Acrylic filter is used in some models. This filter sho

-

uld be replaced at least once every two months or 

more frequently if the appliance is used intensively.

Charcoal filter (only the recirculation version)

Operation - Carbon filters can be used only when 

the hood is not connected to any ventilation duct. 

Filters with active carbon can absorb odours until 

they are saturated. They cannot be washed or re-

generated and should be replaced at least every 2 

months or more frequently in case of very intensive 

use.

Replace: 

Dismantling of charcoal filter is shown on Figure 6.

Lighting

See Figure 7 for details how to replace lights. Use 

incandescent / halogen / LED modules of the same 

specification  as  those  factory-installed  in  the  ap

-

pliance.

Cleaning

Normal hood cleaning:

l

  Do not use a soaked cloth, sponge, or water 

jet.

l

  Do not use solvents or alcohol, as they may 

tarnish lacquered surfaces.

l

  Do not use caustic substances, especially for 

cleaning stainless steel.

l

  Do not use a rough or abrasive cloth.

It is recommend to use a damp cloth and a neutral 

detergent.

Aluminium filters may be washed in the dishwash

-

er. The colour of aluminium filters may change after 

several washings. This is normal and it is not nec-

essary to renew the filters.

Summary of Contents for IN 900 BIC UK

Page 1: ...IN 900 BIC UK INSTRUCTION MANUAL KITCHEN EXTRACTOR HOOD EN Before using the appliance please carefully read this manual ...

Page 2: ...2 ...

Page 3: ...3 ...

Page 4: ...4 min 650mm Gas cookers min 650mm Gas cookers min 450mm Electrical cookers 1a 1b 1c 2a 3a 3b ...

Page 5: ...5 3c 3d 3e 3f 3g 3h ...

Page 6: ...6 3i 3j 3k 3l 3m 3n ...

Page 7: ...7 4 6 5a 5b ...

Page 8: ...e hood They will help you avoid mistakes during installation and operation of the hood We wish you a lot of satisfaction from choosing our kitchen extractor hood DEAR CUSTOMER THANK YOU FOR PURCHASING AN AMICA APPLIANCE Symbols appearing in these instructions have the following meaning This indicates actions than must not be performed by the user Risks resulting from improper operation of the appl...

Page 9: ...iture cooker hoods operating in air recircu lation mode l Cooker hood operating in air recirculation mode requires the installation of an activated charcoal filter In this case instal ling an extractor duct is not required however it is recommended to in stall an air guide vane chimney cooker hoods only i l The cooker hood featu res independent lighting and exhaust fan that can be operated at one ...

Page 10: ...ll socket before any filter cleaning or repair op eration l The textile grease fil ter should be replaced and the aluminium filter should be cleaned at least every one month in connection with the existing fire danger saturated fat is very flammable l If any other non electric devices are used in the same room as the hood e g liquid fuel ovens flow through or volu metric water heaters it is necess...

Page 11: ...age indicated on the rating plate corresponds to the local power supply parameters l Before installing un wind and straighten the power cord l Warning The pack aging materials poly ethylene bags small pieces of foamed poly styrene etc should be kept away from children while unpacking l NOTE Before con necting the hood to the mains power sup ply always check that the power cord is prop erly install...

Page 12: ...is option filtered air returns to the room through openings in the front of the hood In this setting it is necessary to install the carbon filter It is recommended to install the air guide availability depending on model In some universal hoods you need to switch lever inside the hood Fig 8 to switch between the extraction and air recirculation modes The cle aned air is returned to the room throug...

Page 13: ...ontrol your cooker hood Fig 4 IN900BIC Touch to turn off the hood Touch to turn lights on off independently of fan operation Touch this sensor briefly to lights on off Operation of hood by induction hob see instruction manual of induction hob page 27 28 ...

Page 14: ...ot connected to any ventilation duct Filters with active carbon can absorb odours until they are saturated They cannot be washed or re generated and should be replaced at least every 2 months or more frequently in case of very intensive use Replace Dismantling of charcoal filter is shown on Figure 6 Lighting See Figure 7 for details how to replace lights Use incandescent halogen LED modules of the...

Page 15: ...spose of the appliance at the waste col lection point authorised by the local author ity The local waste collection points shops and communal units form an appropriate system enabling the disposal of the equip ment Handling the used electrical and electronic equipment and any hazardous substances contained therein in a correct manner is vi tal to avoid damage the local natural envi ronment Therefo...

Page 16: ...IO HOO 0272 1 06 2016 01 883 2010 ...

Reviews: