WIRING DIAGRAM
Important! Heating elements operate at 230V.
Important! For each connection the protective conductor must be connected to the
terminal marked .
Aanbevolen
type aanslu
-
itkabel
1
230 V single phase connection
with a neutral lead, terminals 1-2-3
are bridged, neutral lead to termi
-
nal 4, and the protective conductor
to
1/N-
~
HO5VV-F3G4
2
400/230 V two phase connection
with a neutral lead, terminals 2-3
are bridged, neutral lead to termi
-
nal 4, and the protective conductor
to
2/N-
~
H O 5 V V -
-F4G2,5
3
400/230 V three phase connecti-
on with a neutral lead, individual
phases are connected to terminals
1, 2, 3 respectively, neutral lead
to terminal 4, and the protective
conductor to
3/N-
~
H O 5 V V -
-F5G1,5
L1=R, L2=S, L3=T, N=neutral lead connection, PE=protective lead terminal
1
L1
N
2
4
3
PE
5
1
L1 L2
N
2
4
3
PE
5
1
L1 L2
N
2
4
3
PE
5
L3