8
| Instruction Manual
Mains electricity connection
THIS APPLIANCE MUST BE CONNECTED TO THE MAINS
SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING
VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND
PROTECTED BY A 3A FUSE.
We recommend that the appliance is
connected by a qualified electrician,
who is a member of the N.I.C.E.I.C.
and who will comply with the I.E.T.
and local regulations.
The wires in the mains lead of
this appliance are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wires in the mains lead for the appliance
may not correspond with the coloured markings identifying the
terminals connecting to the fuse spur, proceed as follows:
•
The wire which is coloured GREEN and YELLOW must be con-
nected to the terminal marked E (Earth) or coloured GREEN and
YELLOW
•
The wire which is coloured BLUE must be connected to the
terminal marked N (Neutral) or coloured BLACK.
•
The wire which is coloured BROWN must be connected to the
terminal marked L (Live), or coloured RED.
FUSE
ON
USE A 3 AMP FUSE
DOUBLE POLE SWITCHED FUSED
SPUR OUTLET