Installation
Design Recommendations
The inlet and outlet pipes must be the same or a larger diameter than the inlet and outlet diameters of the filter.
The upstream pressure source should not drop below 30 psi (2 bar) during the rinse cycle. If this cannot be ensured, consult the
manufacturer.
If a prolonged pipeline fill time causes a temporary high flow and low pressure situation, it recommended that you install a
pressure sustaining valve downstream of the filter. The pressure sustaining valve will ensure a controlled fill-up of the line.
If continued water delivery is essential even during “down time” maintenance periods, it recommended that a manual or
automatic by-pass be installed, and that isolating valves be installed up and downstream of each filter unit for isolation purposes.
Shut off valves must be installed in the inlet and outlet lines to enable maintenance.
A non-return valve should be installed where water hammer or back flow may be a problem.
The filter must be installed in the direction of flow indicated by the arrow on the filter body.
Secure the drain pipe so that there is no movement during flushing.
The highest point of the drain pipe should be no more than one half meter above the filter.
The drain pipe must allow free flow and be free of restrictions.
Preparations for Installation
Ensure suitable lighting at the area of the filter to enable good visibility and safe maintenance.
Arrange suitable platforms and safety barriers to enable easy, safe access to the filter.
Allow a convenient approach and enough space for dismantling and maintenance.
Installation Instructions
Ensure the direction of flow is according to arrows marked on the filter housing
Install a drain valve in place of one of the pipe plugs in the inlet or outlet pipe on the installation manifold.
Important!
Prevent static back pressure or reverse flow through the filter.
Install a manual or a hydraulic valve downstream of the filter.
The filter may enter flushing mode automatically, without warning.
Summary of Contents for Filtomat MG114
Page 8: ...MG114 910101 000554 12 2019 Page 8 of 31 Dimensional Drawings ...
Page 16: ...MG114 910101 000554 12 2019 Page 16 of 31 4 Pull the coarse screen out of the filter housing ...
Page 18: ...MG114 910101 000554 12 2019 Page 18 of 31 C D E B ...
Page 23: ...MG114 910101 000554 12 2019 Page 23 of 31 Parts Drawing 1 Page 1 of 2 ...
Page 24: ...MG114 910101 000554 12 2019 Page 24 of 31 Parts Drawing 1 Page 2 of 2 ...
Page 26: ...MG114 910101 000554 12 2019 Page 26 of 31 Dirt Collector Parts Drawing ...
Page 28: ...MG114 910101 000554 12 2019 Page 28 of 31 Cover Parts Drawing ...
Page 29: ...MG114 910101 000554 12 2019 Page 29 of 31 Control Tubes Scheme ...