
M104LPN, M106LP Electronically Controlled 910101-000484 / 12.2019
Page 15 of 31
Servicing
Draining the Filter
1.
Close the filter’s upstream (inlet) valve.
2.
Close the filter’s downstream (outlet) valve and isolate the filter from the water system.
3.
Use the manual start function of the electronic flushing controller and start a flushing cycle to release the
pressure of the filter housing.
Removing the Screen and the Dirt Collector
1.
Drain the filter as described above.
2.
Unscrew and remove the nuts from the filter’s lid bolts [1]
but do not remove the long bolt nut!
[2]
3.
Open the lid by pulling it [3] and carefully leave it to hang on the long bolt [4].
Do not remove the long bolt’s nut!
Note:
Attempting to remove the screen from the piston-side of the filter will cause damage to the system.
1
2
4
4
3