ADI-P
910101-000992 / 0
5.20 0
2
Page 19 of 21
Annex B.
Connecting the ADI-P Controller to a DC external power source:
General:
The ADI-P system is powered by 4X1.5V AA consumer alkaline batteries (non-rechargeable, safety approved)
and/or by external safety approved external DC power supply 7-14VDC, max 1A (not provided with equipment).
Safety First:
When connecting the external power supply
•
Make sure to comply with all the general and local regulations and standards required for connecting an
indoor / outdoor external power source.
•
All external connections must be done by an authorized electrician with qualifications to perform this type
of work.
Type of Adaptor (Not supplied by Amiad)
•
The adaptor should be a standard DC adaptor that supplies 7-14 VDC at its output connection.
•
The system must be protected by a max 1A external fuse and it must use a minimum of 22 AWG wires.
Connections and Connection Drawing
•
The DC output of the adaptor should be connected to the J1 terminal strip of the controller to the:
Power In (+) and Power In (
–
) connectors.
•
For backup during power outages, the batteries may be left in place within the controller.
DO NOT USE RECHARGEABLE BATTERIES!
J2
1
1
8
8
J1