background image

 

 

 

INSTALLATION AND MAINTENANCE INSTRUCTIONS: 1"-SUPER FILTERS  

(AP010B.SA0.0001) 

 
Thank you for selecting an Amiad filter. This filter has been designed to provide years of trouble free service. Please 
familiarize yourself with these instructions to ensure correct and reliable operation. 

 

INSTALLATION 

1.  Amiad recommends using plastic connectors when 

installing the filter onto metal pipes. 

2.  Use only Teflon or silicon sealing material on  the 

inlet/outlet  connections.  Do  not  use  any  sealing 
material  on  the  plastic  ball  valve  connection  to 
the filter drain port. (SCREEN  FILTER ONLY) This 
is a compression type fitting and does not require 
any sealing material. 

3.  Install  a  shut-off  valve  before  the  filter  to 

facilitate cleaning. 

4.  Install  the  filter  with  the  housing  oriented 

downward.  Make  sure  to  install  according  to  the 
direction  of  water  flow  as  shown.  This  filter  is 
available  with  either  a  Screen  cylinder  or  Disc 
element.  Be  sure  the  direction  of  flow  is 
inside/out  for  the  Screen  cylinder  and  outside/in 
for the Disc element. See drawing. 

 
 
 
 

CLEANING 

The  filter  requires  cleaning  when  pressure  drop 
between the inlet and outlet reaches 0.5-0.6 bar (7-
8 psi). 
 
 
 

 
1.  Close  the  water  supply  to  the  filter  and  release 

pressure from the system. 

2.  Unscrew the lid to remove the filter element. 
3. 

Screen  cylinder:

  Rinse  the  screen  with  water. 

Use a soft brush for hard-to-remove particles. Do 
not  use  a  metal  brush  which  may  damage  the 

screen. 

 

Disc element:

 Twist the disc element core at each end and unscrew in a counter- clockwise direction. This loosens 

the disc core. Direct a stream of water along the disc edges to rinse with a spinning action. Hand-tighten the disc 

element core after cleaning. 

4.  Insert the filter element into the housing. Make sure that the housing and element seals are in place. Screw on the 

lid until tight, then back-off 1/8 turn for proper sealing. 

5.  Close the drain valve and open the inlet valve to pressurize the filter. Check and correct any leaks. 
 

Maximum pressure drop across the filter element, for a short time should not exceed 6 bar (90 psi). 

 
An optional accessory for semi-automatic operation of the 1"-Super filter (screen element only!) is the Torpedo: By 
inserting the Amiad Torpedo (cat. no. NBZZZ.00241) and mounting a manual or automatic flushing valve, the unit 
will  become  a  Turboclean  filter.  The  Turboclean  filter  reduces  maintenance  and  is  an  ideal  solution  as  a  sand 
separator.  

  For more information, please consult your Amiad dealer. 

WARNING: 

Improper flow direction or backflow 

through a screen may damage the filter element. 
 

WARNING: NEVER OPEN THE FILTER WHILE 
UNDER PRESSURE! 

 

Reviews: