n

Switch  on  the  power  supply

n

Wait approximately for half  an hour so that the

storage  tank  fully  fills  up**

n

Switch  off   the  power  supply

n

Drain off  the storage tank by opening the faucet
to remove any dust particles from the pipe and
storage tank

n

Close  the  faucet  &  switch  on  the  power  supply

n

The purifier is ready to use

Starting-up  the  Purifier

TDS  Adjustment*

Although the rejected water has high concentration 

of  salts, it is absolutely clean and free of  impurities 

like chlorine, dirt, sand, etc. which are present in raw 

water. This  rejected  water  usually  goes  down  the 

drain  but  if   required,  can  be  used  for  gardening 

purposes.  It  has  high  concentration  of   salts  and 

minerals which accelerates plant growth. Rejected 

water can also be used for cleaning purposes, i.e. 

cleaning  utensils,  mopping, etc.

Recommended  Usage  of   Rejected  Water

Figure 2

3 Way Connector

SS Ball Valve

90 Degree
Ball Valve

The unique TDS Controller enables customers to retain the contents of  natural minerals in purified water as per 
their requirement.

n

 

Turning  the  screw  of   the  valve  clockwise

results  in  a  decreased  mineral  content

n

Turning  the  screw  of   the  valve  anticlockwise

results  in  an  increased  mineral  content

Note: 

The purification capacity of  RO membrane will reduce with   time   due   to   clogging   of    pores   of   

membranes.

To  ensure  tha t  the  purifier  opera tes  a t  its 
optimum  level,  a  routine  maintenance  must  be 
performed. The frequency of  the maintenance will 
greatly  depend  upon  the  raw  water  quality  and 
consumption  of   purified  water.

n

  Replace sediment, activated carbon block and

UF filter when the filter change alarm is audible
OR after every 12 months. It is recommended to
change the FRT when the filters are replaced

n

Replace  RO  membrane  once  in  a  year

n

Replace  UV  Lamp  once  in  a  year

n

If  you are not going to use the purifier for a long

time (in case you are on a holiday, tour or out of
home), make sure that you disconnect the power
supply, turn off  the raw water supply and drain
the  storage  tank

Maintenance

“This reverse osmosis system contains a replaceable component critical to the efficiency of  the system. 
Replacement of  the reverse osmosis component should be with one of  identical specifications as defined by 
the manufacturer, to ensure the same efficiency and contaminant reduction performance.”

The Reverse Osmosis system contains a replaceable treatment component critical for the effective reduction 
of   total  dissolved  solids  and  that  product  water  shall  be  tested  periodically  to  verify  that  the  system  is 
performing properly.

Replacement of  spare parts are as under:-

Important Safety Instructions

n

If  the supply cord is damaged, it must be replaced by the original part in order to avoid hazard

n

Children should be supervised to ensure that they do not play with the appliance

Warning

n

Do not operate the UV-C emitter when it is removed from the appliance enclosure

n

Read the maintenance instructions before opening the appliance

n

The appliance must be disconnected from the supply before replacing the UV-C emitter

H-F1005CF 

H-F2510GAC 

M-T1808-ENK 

H-F083

4

-43

ST

M-U1808 

H-

L11W

H-F2510AC 

Sediment Filter  10”

Activated Carbon  Filter  10”

RO Membrane Welded  8" Housing

 

Post Carbon Filter (Blue)

Hollow Fibre Membrane (UF)

 

Ultraviolet (UV) Replacement Lamp

 

Carbon Block Filter 10”

n

If  the supply cord is damaged, it must be replaced by the original part in order to avoid hazard

n

Children should be supervised to ensure that they do not play with the appliance

n

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
mental capabilities, or lack of  experience and knowledge, unless they have been given supervision or 
instruction concerning use of  the appliance by a person responsible for their safety

To Drain

Summary of Contents for Pure Plus Mineral RO HD-22PP

Page 1: ...anes com Instruction Handbook for Installation Operation and Maintenance The Best Tasting Pure Water Applied Membranes Inc is an ISO 9001 2015 QMS Certified Company AMI PURE PLUS FOR WALL MOUNTING UNDER THE COUNTER COOLER INSTALLATION Member of Reverse Osmosis Water Purification with UV Disinfection TDS Controller ...

Page 2: ...out of your water purifier Please go through this booklet to familiarize yourself with its operation andmaintenance Best Wishes Applied Membranes Inc 1 AMI TECHNOLOGY A Breakthrough in Water Purification 1 2 Features 1 3 Items in the Box 1 4 Important Instructions 2 5 Reverse Osmosis Process 3 6 UV Process 3 7 Water Flow Diagram 4 8 Electrical Circuit Diagram 4 9 UV Fail Alarm 5 10 Filter Change A...

Page 3: ...water into sweet and purer drinking water It also incorporates a UV disinfection process to give double protection from harmful TM micro organisms The AMI Pure Plus Mineral RO Water Purifier also allows the user to control the Total Dissolved Solids TDS level of purified water AMI TECHNOLOGY A Breakthrough in Water Purification Items in the Box TM 1 AMI Pure Plus Mineral RO Water Purifier 1 Qty 2 ...

Page 4: ...ter and thus do not get accumulated as in a traditional filter UV Process The UV light has shorter wavelength higher energy than the visible light It is called Pure Plus violet because it is just beyond violet light in the light spectrum Technically the Pure Plus violet light is defined to be any wavelength of light which is shorter than 400 nanometer UV rays which penetrate into the micro organis...

Page 5: ...itchen bed where the faucet labeled as No 16 in the system flow chart can be installed conveniently as per drawing Secure the faucet to the sink by tightening the brass nut washer n Tighten the 90 degree ball valve to the tank and connect it to the outlet of the purifier as shown in the drawing Installation Instructions 246 mm Figure 1 UV Fail Alarm To ensure delivery of purer and healthier water ...

Page 6: ...vated carbon block and UF filter when the filter change alarm is audible OR after every 12 months It is recommended to change the FRT when the filters are replaced n Replace RO membrane once in a year n Replace UV Lamp once in a year n If you are not going to use the purifier for a long time in case you are on a holiday tour or out of home make sure that you disconnect the power supply turn off th...

Page 7: ...entavalent arsenic Arsenic does not generally impart color taste or smell to water therefore it can only be detected by a chemical analytical test Public water supplies are required to monitor treated water for total arsenic trivalent arsenic plus pentavalent arsenic and the results are available to the public from the utility Consumers using private water sources will need to make arrangements fo...

Page 8: ......

Reviews: