AMG5514R Instruction Sheet D17366-
00.doc 
 

 

 

Connections 

Optical Connections Singlemode 

No. of Optical Connections .................. 1 
Optical Fibre ........................................ Singlemode   
Connector ............................................ SC/PC 
 
Primary Optical Launch Power ............ -10dBm 
Transmit Wavelength ........................... 1310nm 
 
Primary Optical Sensitivity ................... -30dBm 
Receive Wavelength ............................ 1550nm 
 
Minimum Optical Dynamic Range ....... 20dB. 
 

 

Power Connection 

Power supply ....................................... From plug in connection on the AMG2009 or AMG2015 subrack 
Power consumption ............................. 3.0 Watts max. 
 

 

Data and Alarm Channel Connections 

No. of Data Channels .......................... 1  
No. of  Alarms ...................................... 1  
 
Connectors .......................................... Removable 8-pin, 2.5mm, Spring Terminal 
Connector Partno. ................................ Phoenix  1881383 
 
Data Interfaces .................................... RS-232, RS-422 or R-S485. Selected by slide switch inside 

enclosure. *See appropriate section on how to remove the case 
for access to the data switches 
 

 

RS-485 – Switch Position - Top  

 

RS-422 – Switch Position - Middle 

 

RS-232 – Switch Position - Bottom 

 
Alarm input ........................................... Contact  Closure pull-up is 330R to +3V3 
Alarm Output ........................................ Solid-state  Relay, maximum 150mA at 125Vac/dc, Ron < 6.5

 

 

 

Summary of Contents for AMG5514R

Page 1: ...ata Channel and one Bi directional Alarm for a Singlemode Fibre Link The AMG5514R is a rackmount receive unit designed to transmit and receive 1 data signal plus 1 Bi directional alarm over one Single...

Page 2: ...ctional Schematic 3 Optical Connection 3 Connections 4 Optical Connections Singlemode 4 Power Connection 4 Data and Alarm Channel Connections 4 Front Panel Indicators 5 Power Opto LED 5 Low Speed Data...

Page 3: ...ion Unit Functional Schematic The AMG5514R transmits 1 data channel and 1 uni directional alarm signal to the AMG5513 transmit unit It also receives 1 data channel and 1 Bi directional alarm transmitt...

Page 4: ...mum Optical Dynamic Range 20dB Power Connection Power supply From plug in connection on the AMG2009 or AMG2015 subrack Power consumption 3 0 Watts max Data and Alarm Channel Connections No of Data Cha...

Page 5: ...n on IN IN Data Present IN RS232 Green logic zero V present on input IN Red logic transitions present on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitt...

Page 6: ...e the enclosure Every data channel as shipped from the factory is set up for RS 485 operation unless otherwise requested The data input for both the RS 485 and the RS 422 modes detects a tri state inp...

Page 7: ...IN OUT B OUT B OUT Note A or B in brackets in the above table refers to RS 485 RS 422 data specification Alarm Channel Configuration The AMG5514R provides one bi directional alarm output contact clos...

Page 8: ...practice when working with optical fibre systems This includes Do not stare with unprotected eyes or with any unapproved collimating device at fibre ends or connector faces or point them at other peo...

Reviews: