AMG AMG3723 Instruction Manual Download Page 7

AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.

Page 7 of 8

AMG3723 Instruction Sheet D18013-
01.doc

Data and Audio Channel Configuration

Data and Audio Channel Configuration

The

AMG3723

and rackmount equivalent

AMG3723R

sends and receives data to/from Channel A.

Channel B is not available. Channel A is a single data interface selectable by the user with the slide
switch on the rear panel.

Data Interface Connections Channel A

Channel A

RJ45 Pin

No.

RS485

[switch high]

RS422

[switch mid]

RS232

[switch low]

Cat 5/6 Cable

Colour Code T568B

1

IN + (A)

GND

White/orange

2

IN - (B)

IN

Orange

3

White/green

4

Blue

5

White/blue

6

Green

7

IN/OUT + (A)

OUT + (A)

N/A

White/brown

8

IN/OUT - (B)

OUT - (B)

OUT

Brown

Note: (A) or (B) in brackets in above table refers to RS485 / RS422 data specification, not Channel A,
Channel B.

Data Channel A Configuration

Channel A is always present and allows for a RS232, RS422 (full duplex, four wire) or RS485 (half
duplex, two wire) interface depending on the position of the switch located above the RJ45 connector.
The switch signifies the presence of the X16004 Low Speed Data/Audio Interface Board. If there are
LED's present on the RJ45 connector then an X16003 Ethernet Interface Board is fitted.

The data input for both the RS485 and the RS422 modes detects a tri-state input condition by
monitoring the differential voltage level across the input. A differential level below 600mV positive or
negative will be detected as a tri-state condition. A level above 600mV positive or negative will be
detected as a logic 1 or logic zero respectively. It is important therefore to terminate the RS485 bus or
the RS422 input bus using 120

Ω

if a pre-bias is present on the RS485 or RS422 bus.

A large number of third party equipment manufacturers apply a pre-bias on their RS485 bus. This pre-
bias is applied by pulling one arm of the RS485 bus high (+5 volts) and the other arm low (0 volts)
using high value resistors within the third party equipment. In order to ensure that the AMG equipment
detects a tri-state condition, then these resistors should have a value above 5k

Ω

. If the third party

bias resistors are less the 750

Ω

the bus can be double or triple terminated as required to ensure that a

tri-state level is detected.

Note: The Data Channel A is shipped from the factory set up for RS485 operation unless otherwise
requested.

Summary of Contents for AMG3723

Page 1: ...is a standalone two channel video insert unit designed to transmit 2 video signals and transmit receive 1 bi directional data channel to from a singlemode optical fibre ring The AMG3723 is designed to...

Page 2: ...n 3 Optical Connection 3 Connections 5 Video Input Connections 5 Optical Connections 5 Power Connection 5 Data and Audio Channel Connections 5 Front Panel Indicators 6 Power LED 6 Video Input LED s 6...

Page 3: ...is 17dB Video Input Channel Configuration At the AMG3723 or rackmount AMG3723R insert unit video signals present at the BNC inputs can be inserted on one to eight video channels transmitted on the op...

Page 4: ...on herein is believed to be accurate No responsibility is assumed by AMG for its use Page 4 of 8 AMG3723 Instruction Sheet D18013 01 doc In a ring system single dual and four channel insert units resp...

Page 5: ...inglemode Primary Optical Launch Power 5dBm Wavelength 1310nm Primary Optical Sensitivity 22dBm Wavelength 1310nm Power Connection Connector Type 2 1mm screw lock long power jack centre positive Conne...

Page 6: ...tical channel receiving but not sync Off optical channel not transmitting Low Speed Data LEDs Channel A Data Present TX RS485 or RS422 Green logic zero V V present on IN IN Red logic one V V present o...

Page 7: ...e RJ45 connector The switch signifies the presence of the X16004 Low Speed Data Audio Interface Board If there are LED s present on the RJ45 connector then an X16003 Ethernet Interface Board is fitted...

Page 8: ...B s out of the case Ensure that the fibres do not snag or get trapped To replace the PCB s into the case slide the PCB s gently into the case aligning the boards with the appropriate slots Ensure that...

Reviews: