electromagnetic interference and temperature fluctuations with condensation lead to 
false alarms. Therefore, the standard for renovations is to cover the smoke detector. 

 

Maintenance / Repair 

 
For your own safety, a periodically check of the fire alarm system should be performed as 
follows: 
 
The weekly review of the LED display on the smoke detector (it must flash 1 x 
all 30 - 60 seconds, depending on the model). 
 
The smoke detector is to check according to the manual, but at least quarterly. 
This includes the examination of whether the smoke inlet openings are freely accessible 
and smoke detector is not damaged. 
Deficiencies in these points should be removed immediately; a damaged smoke detector 
must be replaced immediately. 
 
 
 
The functional test of the smoke detector is to test the alarm by pressing the test button 
or use our tester spray. 
 
The battery change has to be with alkaline batteries within 12 months and with lithium 
batteries at least every 5 years, please also if the battery has not been triggered a weak 
message. 
 
The annual cleaning of the test chamber of the smoke detector can be done with a 
vacuum cleaner to remove dust in the smoke detector. In this case, put the vacuum 
cleaner directly on the smoke detector in every crack and corners for 1 min. 
 
Please use our enclosed maintenance & testing protocol to keep the maintenance status 
of the fire alarm system at a glance. 
 

Battery change 

 
The battery should be substituted in smoke detectors at least once a year or according to 
the manufacturer's instructions (e.g. if batteries with longer maturity are used). 
But at the latest on the acoustic signaling of the necessary battery change.  
 
Please choose in the view of the delivered model 
 

Summary of Contents for BMS 03

Page 1: ...ee from landlines and all German mobile networks 22 12 2014 18 1 Program a smoke detector 2 2 Delete all smoke detectors 2 3 End of an alarm 3 4 Specifications headquarters 3 5 User manual smoke detec...

Page 2: ...by the unit 1 4 You now send the signal of the smoke detector twice by pressing the Test button on the smoke detector until it starts to beep and from the panel also comes a short beep Please repeat...

Page 3: ...vice In addition you have the option of the siren either ON or OFF For this purpose press the RESET button The BUZZ button is to stop only the internal signal generator Note The yellow LED on the pane...

Page 4: ...al and audible indication when battery replacement is required The minimum equipment of smoke detectors required are in the nursery sleeping area and hallway An optimum is if every room is equipped wi...

Page 5: ...a max width of 3m the allowed distance between two smoke detectors is max 15 m The distance from one end of the corridor or passage to the other must not exceed 7 5m Smoke detectors in draughty points...

Page 6: ...plied as described in the standard DIN EN 14604 will be able to work both as an individual detector as well as with other smoke detectors in an network A network requires special detectors such as tho...

Page 7: ...rooms heating and work rooms and attic In stairwells or rooms with a gallery is at least to install one smoke detector on the top of the floor Better however would be a smoke detector on each level I...

Page 8: ...ke detector is not damaged Deficiencies in these points should be removed immediately a damaged smoke detector must be replaced immediately The functional test of the smoke detector is to test the ala...

Page 9: ...w amg sicherheitstechnik de info amg sicherheitstechnik de Business hours are 9 17 clock outside this time an answering machine is running Free from landlines and all German mobile networks Summary DI...

Page 10: ...f the smoke detector using test facility to check In addition instructions must be provided for the mounting location installation and maintenance In addition on the product must be the symbol for the...

Reviews: