electromagnetic interference and temperature fluctuations with condensation lead to
false alarms. Therefore, the standard for renovations is to cover the smoke detector.
Maintenance / Repair
For your own safety, a periodically check of the fire alarm system should be performed as
follows:
The weekly review of the LED display on the smoke detector (it must flash 1 x
all 30 - 60 seconds, depending on the model).
The smoke detector is to check according to the manual, but at least quarterly.
This includes the examination of whether the smoke inlet openings are freely accessible
and smoke detector is not damaged.
Deficiencies in these points should be removed immediately; a damaged smoke detector
must be replaced immediately.
The functional test of the smoke detector is to test the alarm by pressing the test button
or use our tester spray.
The battery change has to be with alkaline batteries within 12 months and with lithium
batteries at least every 5 years, please also if the battery has not been triggered a weak
message.
The annual cleaning of the test chamber of the smoke detector can be done with a
vacuum cleaner to remove dust in the smoke detector. In this case, put the vacuum
cleaner directly on the smoke detector in every crack and corners for 1 min.
Please use our enclosed maintenance & testing protocol to keep the maintenance status
of the fire alarm system at a glance.
Battery change
The battery should be substituted in smoke detectors at least once a year or according to
the manufacturer's instructions (e.g. if batteries with longer maturity are used).
But at the latest on the acoustic signaling of the necessary battery change.
Please choose in the view of the delivered model