Specifications
| 2-7
WARNING – PRESSURIZED ENCLOSURE
This enclosure shall not be opened unless the area is known to be free of flammable
materials or unless all devices within have been de-energized.
Refer to Analyzer instruction manual for purge system instructions.
PURGE GAS IS AIR OR NITROGEN
Power shall not be restored after enclosure has been open until enclosure has been
purged for 5 minutes at a flow rate of 225 L/min or more.
WARNING: The safety of this equipment relies on the provision of proper purging and
pressurizing when used in hazardous locations. It must not be put into use without
“Special Permission” from the inspection authority having jurisdiction.
Overpressure: 0.5 mbar (0.2”wc) min. 2 mbar (0.8”wc) nom, 10 mbar (4”wc) max.
Supply Pressure 4.15 bar (60 psi)min. 5.0 bar (72.5 psi) max.
Max. Leakage Rate: 15 LPM @ 10 mbar overpressure
Protective Gas Flow Requirements 225 Lpm min.
WARNING: When nitrogen is used as purge gas, there may be an asphyxiation hazard.
Special Condition of Use
• Repairs of flameproof joints must be made in accordance with struc-
tural specifications provided by the manufacturer.
• Repairs must not be made on the basis of the values provided in Table
1 or 2 of IEC/EN 60079-1.
• The installer must install appropriate protection from light to ensure
that the resistance to light of the IPS-4, or parts of the IPS-4 is satisfac-
tory.
• The installer must ensure that the installation minimizes the risk from
electrostatic discharge.
Summary of Contents for Western Research IPS-4
Page 48: ...2 18 IPS 4 Dual Bench UV IR Analyzer This page intentionally left blank...
Page 140: ...4 48 IPS 4 Dual Bench UV IR Analyzer This page intentionally left blank...
Page 172: ...5 32 IPS 4 Dual Bench UV IR Analyzer This page intentionally left blank...
Page 178: ...6 6 IPS 4 Dual Bench UV IR Analyzer This page intentionally left blank...
Page 218: ...A 2 IPS 4 Dual Bench UV IR Analyzer Analyzer Light Path UV Optical Bench Schematic...
Page 219: ...Appendix A Drawings A 3 Analyzer Light Path NDIR Optical Bench Schematic CONDENSING...
Page 222: ...A 6 IPS 4 Dual Bench UV IR Analyzer Detector Board 100 2046...
Page 223: ...Appendix A Drawings A 7 Display Interface Board 100 2049...
Page 225: ...Appendix A Drawings A 9 AC Disconnection Board 100 2077...
Page 227: ...Appendix A Drawings A 11 Relay Board 100 2050...
Page 228: ...A 12 IPS 4 Dual Bench UV IR Analyzer Analog Board 100 2047...
Page 229: ...Appendix A Drawings A 13 MCU Board 100 2045...
Page 230: ...A 14 IPS 4 Dual Bench UV IR Analyzer Xenon Lamp Power Supply Board 100 2061 UV Optical Bench...
Page 231: ...Appendix A Drawings A 15 Infrared Source Assembly Interface Board 100 2838 IR Optical Bench...
Page 232: ...A 16 IPS 4 Dual Bench UV IR Analyzer Electronics Enclosure Wiring Diagram Sheet 1 of 5...
Page 233: ...Appendix A Drawings A 17 Electronics Enclosure Wiring Diagram Sheet 2 of 5...
Page 234: ...A 18 IPS 4 Dual Bench UV IR Analyzer Electronics Enclosure Wiring Diagram Sheet 3 of 5...
Page 235: ...Appendix A Drawings A 19 Disconnect Enclosure Wiring Diagram Sheet 4 of 5...
Page 236: ...A 20 IPS 4 Dual Bench UV IR Analyzer Disconnect Enclosure Wiring Diagram Sheet 5 of 5...
Page 238: ...S 2 IPS 4 Dual Bench UV IR Analyzer This page intentionally left blank...