Ametek Teseq TWT Series Quick Start Manual Download Page 5

AMETEK CTS 

 

TWT Amplifiers  

Quick Start and Safety Guide 

V 1.0 

5 / 10 

 

 

WARNING: Do not touch the inner conductor of the RF-output connector.

 

High voltages can occur on the inner conductor of the RF output connector, or on cables or anten-

nas connected to it. These can cause RF burns if touched. 

 

 

WARNING

:

 The Amplifier is required to be connected to a suitable ground point.

 

The amplifier conforms with IEC Safety class 1, meaning that it is provided with a protective ground-

ing terminal.  This is through the line supply cord to the centre pin of the power inlet connector. To 

maintain this protection, the line supply cord must always be connected to the source of line supply 

via a socket with a grounded contact.  Do this before making connections to the RF-input or RF-

output connectors of the amplifier. 

 

Without the protective ground connection, all parts of the amplifier constitute a potential shock hazard. 

 

 

WARNING: Use the correct power cord.

 

Use only the line supply cord and connector specified for the amplifier. Use only a line supply cord 

that is in good condition. 

 

 

WARNING: Do not remove covers or panels.

 

To avoid personal injury, do not operate the amplifier without the panels or covers in place. Remov-

al of panels will expose the operator to high voltages that can remain in the amplifier after being 

switched off for some time. 

 

 

WARNING: Do not operate in explosive atmospheres.

 

The amplifier provides no explosive protection from static discharges or arcing components. Do not 

operate the amplifier in an atmosphere of explosive gasses. 

 

 

CAUTION: Avoid static discharges.

 

The RF input and output connections are static-sensitive and should 

not be subjected to static dis-

charge. 

 

 

CAUTION:

 

Do not obstruct the circuit breaker.

 

Ensure that there are no obstructions that impair the operation of the rear panel line-supply circuit 

breaker(s). 

 

 

CAUTION: Do not obstruct the airflow through the amplifier.

 

The cooling airflow is drawn in through the front and exhausted at the rear.  If this airflow is ob-

structed, overheating of the amplifier may occur. 

 

 

CAUTION: Do not operate the amplifier outside its specification.

 

This may cause the amplifier to malfunction or be damaged. 

 

 

WARNING: Do not touch the exterior of the amplifier (rack mount version) when in use.

 

The top and side panels of the amplifier can get hot during use, especially on high power models. 

 

 

CAUTION: Periodically replace the air-intake filters.

 

Operating the amplifier with the air filters dirty may cause the amplifier to overheat.  

 

 

CAUTION:

 

Exercise caution when lifting. 

 

 

The appropriate lifting practices should be observed during transportation, installation, or removal of the amplifi-

er from its mounting position. 

 

 

 

 

 

 

 

Summary of Contents for Teseq TWT Series

Page 1: ...Version 1 0 31 3 2021 Replaces Filename Quick Start and Saftey TWT Amplifier Series_1 1 docx Print date 4 29 202121 QUICK START GUIDE AND SAFETY INSTRUCTIONS TWT Amplifiers Teseq TWT Series...

Page 2: ...and Safety Guide V 1 0 2 AMETEK CTS GmbH Sternenhofstrasse 15 4153 Reinach BL1 Switzerland Phone 41 61 204 41 11 Fax 41 61 204 41 00 URL www ametek cts com Copyright 2021 AMETEK CTS GmbH All right res...

Page 3: ...n 7 2 4 Connecting the RF cables 7 2 5 Connecting the Safety interlock 8 2 6 Connecting an RF Load and Signal Generator 8 2 7 Line supply input connector 8 3 Quick Start 9 3 1 Rear Panel Connections 9...

Page 4: ...tact with these voltages This symbol indicates where a caution is required Refer to the operating instructions lo cated in the manual to protect against personal injury or damage the equipment When us...

Page 5: ...operator to high voltages that can remain in the amplifier after being switched off for some time WARNING Do not operate in explosive atmospheres The amplifier provides no explosive protection from s...

Page 6: ...ed as a danger area A barrier should be established around any such area with a switch in place when the barrier is broken This switch can be linked to the safety interlock BNC connector on the rear o...

Page 7: ...e may be within the amplifier s specification the internal temperature may rise above operational limits if it is operated in direct sunlight The cooling airflow is drawn in through the front and exha...

Page 8: ...ION Ensure the RF output of the amplifier is connected to a suitable load that is rated for the frequency and peak RF output of the amplifier Do not switch the amplifier on without the RF output conne...

Page 9: ...t the unit with a short 1 s pulse and slowly widen back to the desired operating pulse width this will help to remove any gas that may have built up in the TWT To avoid TWT Arcs and damage caused by e...

Page 10: ...intake filter on the amplifier front panel should periodically be checked for cleanliness If it is seen to be obstructed with any dust or debris this should be cleaned away before the amplifier is op...