Installation
Load Connection
44
Operating Manual for XHR Series Power Supply
60 V to 600 V Models
The output connector for the 60 V to 600 V models is a 4-terminal, wire clamp
connector located on the rear panel. Two of the terminals are for local sense
connections. See
To prepare and connect the load wiring:
1. Strip insulation 0.35in. (9 mm) at the end of the wires.
2. Loosen the terminal screw, insert the stripped wire into the terminal, and tighten
the screw securely.
Figure 2.5
Output Connector
(For 60 V to 600 V models.)
WARNING
To protect personnel against accidental contact with hazardous voltages, ensure
that the load, including connections, has no live parts which are accessible. Also
ensure that the insulation rating of the load wiring and circuitry is greater than or
equal to the maximum output voltage of the power supply.
SNS +
+
SNS
–
Output
Connector
Load Wires