
Installation
2-24
TM-F2OP-C1XN-01
4. To prevent ground loops, ground the sense line shield, at one point
only, to the power supply’s return output connection at the load, to the
power supply’s return output at its negative output terminal, or to the
power supply’s chassis.
5. Turn the power supply ON.
Notes:
1. If you operate the power supply with remote sense lines connected to
the load and with either of the positive or negative load lines not
connected, the power supply shutdown circuit will activate, causing
the output voltage and current to fall to zero.
2. If you operate the power supply without remote sense lines or local
sense jumpers in place, the supply will continue to work, but supply
regulation will be degraded and/or erratic, or, the OVP circuit may
activate.
Figure 2-12 shows a sample setup for using remote sensing.
Figure 2-12
Connecting Remote Sense Lines
Summary of Contents for Sorensen XFR 100-28
Page 3: ...This page intentionally left blank ii...
Page 5: ...This page intentionally left blank iv...
Page 7: ...This page intentionally left blank vi...
Page 13: ...xii...
Page 15: ...xiv...
Page 25: ...1 10...
Page 67: ...3 18...
Page 73: ...Remote Operation 4 6 TM F2OP C1XN 01 Figure 4 1 Connecting Programming Sources to J2 Connector...
Page 75: ...4 8...
Page 87: ...5 12...