Operation
Sorensen SGA Series
3-26
M550129-01 Rev AF
CAUTION!
If the power supply is operated with load power lines
disconnected and remote sense lines connected, internal
power supply damage might occur, since output load current
could flow through the remote sense terminals.
To use remote voltage sensing, connect the power supply as described in
Figure 3-23 for the 10V-800V models, and in Figure 3-24 for the 1000V
model. A shielded, twisted-pair cable is recommended to avoid potential
noise interference.
3
1 2
Power
Supply
Output
J3-1: Sense (+)
J3-2: Sense (-), 10V-600V Only
Load
J3
+
-
J3-3: Sense (-), 800V Only
Figure 3-23. Remote Sense Connection at the Load, 10V-800V Models